SSI700 User Manual Description of Function Codes
www.ssinverter.info
The SSI700 provides totally four groups of acceleration/deceleration time for selection.
You can perform switchover by using a DI terminal.
•
Group 1: P0-17, P0-18
•
Group 2: P8-03, P8-04
•
Group 3: P8-05, P8-06
•
Group 4: P8-07, P8-08
Property
Default
Setting
Range
Parameter
Name
Function
Code
Group P0: Standard Function Parameters
★
1
0:1s
1: 0.1s
2: 0.01s
A
cceleration
/
D
eceler
ation
time unit
P0-19
To satisfy requirements of different applications, the SSI700 provides three acceleration/
deceleration time units, 1s, 0.1s and 0.01s.
Notes
Modifying this parameter will make the displayed decimal places change and corresponding
acceleration/deceleration time also change.
Property
Default
Setting
Range
Parameter
Name
Function
Code
Group P0: Standard Function Parameters
☆
0.00
Hz
0.00 Hz to maximum
frequency(P0-10)
Frequency offset of auxiliary
frequency source for A and B
operation
P0-21
This parameter is valid only when the frequency source is set to "A and B operation". The
final frequency is obtained by adding the frequency offset set in this parameter to the A
and B operation result.
Property
Default
Setting
Range
Parameter
Name
Function
Code
Group P0: Standard Function Parameters
★
2
1: 0.1 Hz
2: 0.01 Hz
Frequency reference
resolution
P0-22
It is used to set the resolution of all frequency-related parameters.
If the resolution is 0.1 Hz, the SSI700 can output up to 3200 Hz. If the resolution is 0.01
Hz, the SSI700 can output up to 600.00 Hz.
Notes
• Modifying this parameter will make the decimal places of all frequency-related parameters
change and corresponding frequency values change.
• This parameter is not resumed when factory setting is resumed.
Property
Default
Setting
Range
Parameter
Name
Function
Code
Group P0: Standard Function Parameters
☆
0
0: Not retentive
1: Retentive
Retentive of digital setting
frequency upon power failure
P0-23
This parameter is valid only when the frequency source is digital setting.
If P0-23 is set to 0, the digital setting frequency value resumes to the value of P0-08
(Preset frequency) after the AC drive stops. The modification by using keys and or
the terminal UP/DOWN function is cleared.
Summary of Contents for SSI700
Page 1: ......
Page 3: ...Safety Information and Precautions...
Page 7: ...Product Information...
Page 12: ...Mechanical and Electrical Installation...
Page 19: ...Operation Display and Application Examples...
Page 42: ...Function Code Table...
Page 64: ...Description of Function Codes...
Page 131: ...EMC...
Page 137: ...Selection and Dimensions...
Page 141: ...Maintenance and Troubleshooting...