23
New Sy
stem S
tart
-
Up and
T
esting
Avoid
runn
in
g
the
system
if
the
vessel
is
in
contam
inated
water,
such
as
in
a
d
irty
harbor
or
canal.
The
system
shou
ld
be
ful
ly
run
tested
before
leaving
port.
It
is
preferable
to
sacrifice
a
filter
by
runn
in
g
the
system
in
turbid
water
rather
than
waiting
to
get
offshore
to
discover
a
problem
or
deficiency
in
the
installation.
If
the
loca
tion
or
wea
ther
pr
even
ts
proper testing
refer
to the sec
tion “Dry Testing.”
1.
First Check That:
Thru
-
hul
l valve
is open
Run Manual/ Run Auto/ Flush Manual
S
w
itch in “Run Auto”
Position
Domestic
fresh water pressure syste
m
must
be on
2.
Open pressure relief valve 1/2 turn !
3.
Power up the system to en
ter
“
Purge Mode”. Note: The watermaker will not run w
ith the
pressure relief valve open unless
it i
s in “Purge Mode”. Instead it will restart twice and
alarm “System
Stal
led”.
Alarm
wi
l
l sound
Disp
lay w
il
l read “Open
Pressure Relief
Now”, Ensure that it is open.
Push the Alarm /Disp
lay button to silence
alarm
Warning
!
Da
mage
may
occur
if
t
he
purge
sequence
is
bypa
ssed
an
d
the
me
mbrane
is
pressuri
zed with storage chemical in it.
U
se this procedure when starting a new watermaker for the first time and
whenever the syste
m
contains preservative or cleaning compou
nds.
Summary of Contents for NEWPORT 400 Mk II
Page 2: ...2 ...
Page 15: ...15 John Guest Super Speedfit ...
Page 22: ...22 ...
Page 49: ...49 Z BRANE OPERATION MANUAL ...