28
Flush Cycle
Adjustment
Before
shippi
n
g
fro
m
the
factory
the
N
ewport
water
maker
flush
cycle
is
s
et
to
fa
ctory
default
s
ettin
gs.
Af-
ter initial start up, and a
n
nually the
reafter, t
he flush cycle should be checked.
The water goi
n
g overboard at
the
end
o
f
the
flus
h
cycle
should
not
taste
salty
(<1000pp
m).
I
f
the
water
at
the
e
nd
of
t
he
flush
is
still
salty,
or
to
min
i
mize
t
he
use
of
fresh
water
during
t
he
flush
cycle,
follow
these
instructions
to
optimi
ze
the
cycle.
First
adjust
the
f
lush
water
p
ressure
regulato
r
.
Remove
the
1/2
inch
vinyl
flush
water
hose
where
it
attaches
to
the
flush
water
inlet
fitt
i
n
g
at
the
feed
pump
module.
Push
the
Auto
store
button.
Water
will
begi
n to flow out of t
he flush
water tube. Using a graduated contai
ner
, allow t
he water to flo
w into t
he con
-
tainer
for
exactly
thirty
seconds,
the
n
push
the
stop
button.
If
more
tha
n
3
quarts
(3
liters)
of
water
went
into
the
bucket
the
pres
sure
regulator
is
s
et
too
hig
h
,
if
les
s
the
2.5
quarts
went
into
the
bucket
the
pres
sure
is too low. Adjust the re
gulator by loosen
i
n
g t
he lock nut a
nd tur
n
i
n
g t
he adjustin
g screw. Test again u
nti
l
the correct flow is achieved. Reconnect the Flush
water tube.
Next
adjust
the
feed
pum
p
flush
speed
.
Mounted
under
the
top
of
the
Feed
Pump
Module,
under
the
MPC box
, is a pump speed controlle
r. On t
he board are two
ma
g
netic switc
hes for adjustin
g t
he pu
mp
mo
-
tor
rpm.
The
switches
are
narrow
silver
colored
bars about
1/2”
(1.5cm)
lon
g.
The
Inc
rease
Speed
switch
is labeled S2 and is located in the cor
ner opposite t
he battery cables.
The Decreas
e Speed switch is labeled
S3
and
is
located
just
above
the
battery
cable
s
and
next
to
the
6
capa
citors.
Each
time
a
small
mag
net
is
placed near the switch
w
hile t
he pump is run
ni
n
g
, a signal
will be sent to the controlle
r, cha
n
gi
n
g t
he speed
settin
g, and t
he pump
will speed up or
slow dow
n slig
htly.
Adjust
the
flush
speed
a
s
follows.
Push
the
Auto
Store
button.
Push
the
Alar
m
display
button
unti
l
the
display
reads
PREF
I
LT
ER
GOOD
R
EP
LACE.
The
flus
h
valve
will
ope
n
a
nd
water
wil
l
flo
w
back-
wards
throu
g
h
the
filters
and
strainers.
After
about
30
seconds
the
backflush
will
end
and
the
feed
pump
will
come
on
,
startin
g
the
for
ward
flush
of
the
Clark
Pump
and
membra
ne.
After
the
feed
pump
starts,
close
the
s
ervice
v
alve
(handle
crossways)
or
the
thru
-
hul
l.
If
the
bar
grap
h
on
t
he
display
begins
to
move
toward
R
EP
LAC
E
on
t
he
gau
ge
t
he
feed
pump
is
tryin
g
to
pu
mp
mo
re
water
t
ha
n
the
Flus
h
modu
le
can
supply, and should be slo
wed dow
n. Turn t
he service valve to Service. Water should flo
w very slowly ou
t
of the
garde
n
hose fitti
n
g. If f
low is
more t
ha
n a trickle, speed up the pump. Opti
mu
m flus
h speed will be
the
speed
at
whic
h
slig
htly
more
water
is
comi
n
g
fro
m
the
flus
h
module
tha
n
t
he
feed
pump
is
pumpin
g.
This
settin
g
wil
l
ensure
t
hat
no
sea
water
is
draw
n
i
n
duri
n
g
t
he
flus
h,
but
f
resh
water
is
not
bei
n
g
wasted
overboard.
Adj
ust
the
Pump
Of
f
time
an
d
Pump
On
t
ime.
The flush begi
ns and ends wit
h the Pu
mp Off Time set
-
tin
g.
Pump
off
time
should
be
set
so
that
the
feed
pump
comes
on
just
as
fresh
water
reaches
the
se
a
cock.
Pump
on
ti
me
should
be adjusted
so
that
the
pump
runs
just
long
enou
g
h
for
Fresh
water
to
reach
the
brine
overboard
fitti
n
g,
t
he
n
stops.
Pump
O
n
and
Pu
mp
Off
ti
mes
can
be
adjusted
fro
m
t
he
laptop
computer
o
r
the
display.
See
the
instructio
ns
in
Section
2.
Flu
sh
duration
must
be
set
the
same
as
or
hig
her
tha
n
t
he
total flush time (t
wo pump off ti
mes plus one pump on ti
me).
Pressure regulator
I
ncrease speed
switch
Decrease
Speed
switch
Summary of Contents for NEWPORT 400 Mk II
Page 2: ...2 ...
Page 15: ...15 John Guest Super Speedfit ...
Page 22: ...22 ...
Page 49: ...49 Z BRANE OPERATION MANUAL ...
Page 53: ...53 ...