3
Newport
Installation Quick S
tart
I
mpor
tant Details fo
r
Installe
r
The
system
mu
st
have
a
dedicated
sea
water
inlet
to
guarantee
a
solid
f
low
of
water
to
the
system.
The
inlet
should
be as
low
in
the
bo
at as
possible
and
with
a
forward
facing
scoop
-
type thru
-
hull fittin
g
instal
led.
Fol
low
the
wire
gau
ge
charts
in
the
instructions!
U
sin
g
lar
ger
wire
than
specified
is
ac-
ceptable.
The
MPC
control
must
have
DC
power
continuou
sly
to
achieve
the
full
benefits
of
the
fresh
water
flush
sy
stem.
The
do
mestic
fresh
water
pressure
must
be
on
and
the
fresh
water tank level maintained. Calculate 5 gallon
s (12L) per flush..
The
MPC
5000
control
must
be
de
-
powered
(DC
power
off)
after
the
system
is
put
in
storage.
If
you
are
separa
ting
the
Clark
Pump/membrane
assembly,
please
review
the
high
pres-
sure tube assembly in
structions. Improper asse
mbly
wi
l
l cause failure!
Run,
test,
then
“sea
trial”
the
complete
system
before
assum
in
g
the
system
i
s
opera-
tional.
If
the
boat
is
in
fresh
or
dirty
water,
see “Dry
testing
the
system.”
After
testing
make
sure
tha
t
th
e
flush
cycle
oper
ates
prop
erly.
The
water
goin
g
overboard
at the end
of the flush should not taste salty (<1000ppm)
Spectra
dealers
are
responsib
le
for
educating
the
vessel
owners
on
the
operation
and
maintenance
of
the
system.
We
r
equest
th
at
you
“walk
through”
the
installation
w
ith
our customer.
Please
have the
owner
fill
out
the
warranty
card.
The
warranty
is
void
if
it
i
s
not
reg
is-
tered.
1.
2.
3.
4.
5.
6.
7.
8.
Thank
you
for your purchase of a
Spectra Newport system.
Properly instal
led
it w
il
l prov
ide
years
of
trouble
free
s
ervice.
Please
p
ay
a
tten
tion
to
the
installation
instructions
and
the
sys-
tem
layout.
Like
any
piece
of
mechanical
equipment
th
e
system
wil
l
require
inspection
and
service
from
ti
me
to
time.
Do
not
place
the
components
in
inaccessible
areas
that
will
pre-
vent
proper
maintenanc
e.
If
you
are
having
a
dealer
install
the
system
for
you,
review
the
location
of
the
components
to
make
sure
that
the
installation
wi
l
l
meet
your
approval
upon
completion.
Both the Newport MkII Feed pump module and the Clark Pump/Membrane module
must be instal
led in a we
ll venti
lated compartment where
temperatures
will not ex-
ceed 120F (48C).
Many engine compartments exceed
this temperature when under-
way. Warranty will be void
if the instal
lation does not meet this requirement.
9.
Summary of Contents for NEWPORT 400 Mk II
Page 2: ...2 ...
Page 15: ...15 John Guest Super Speedfit ...
Page 22: ...22 ...
Page 49: ...49 Z BRANE OPERATION MANUAL ...
Page 53: ...53 ...