background image

F64G Filter 

Installation & Maintenance Instructions

 6/15

I&M/en 8.240.100.01

Our policy is one of continued research and development. We therefore reserve the right to amend,  

without notice, the specifications given in this document. (1999 - I&M8074d) © 2015 IMI International s.r.o.

Fluid: Compressed air
Maximum pressure:
Guarded transparent bowl: 10 bar (150 psig)
Metal bowl: 17 bar (250 psig)
Operating temperature*: 
Transparent bowl: –20° ... +50°C (0° ... +125°F)
Metal bowl: –20° ... +80°C (0° ... +175°F)
* Air supply must be dry enough to avoid ice  
formation at temperatures below +2°C (+35°F).
Particle removal: 5 µm, 25 µm or 40 µm filter 
element
Air quality: Within ISO 8573-1, Class 3 and 
Class 5 (particulates)
Typical flow with 40 µm element, 6,3 bar (90 
psig) inlet pressure and 0,5 bar (7 psig) droop 
from set:  70 dm

3

/s (148 scfm)

Automatic drain connection: 1/8”
Automatic drain operating conditions: 
Pressure: 0,7 bar (10 psig). Drain opens when 
bowl pressure drops below 0,2 bar (3 psig).
Minimum air flow: 1 dm

3

/s (2 scfm) required to 

close drain
Nominal bowl size: 0,2 litre (7 fluid oz)
Materials:
Body: Zinc
Bowl:
Metal: Aluminium
Transparent, optional: Polycarbonate
Metal  bowl  liquid  level  indicator  lens,  standard:        
Grilamid
Metal bowl sight glass, optional: Pyrex
Element: Sintered plastic
Elastomers: Synthetic rubber

Replacement Items

Service kit, contains required items circled:  
  

 

4380-200

Prismatic sight glass   

4380-040

Pyrex sight glass     

4380-041

Filter element, 5 µm   

4338-01

Filter element, 40 µm  

 4338-02

Manual drain  

 

 684-84

Automatic drain   

 

3000-97

Mechanical service Indicator (1)   5797-50

Installation

1. Install unit vertically in air line -
• vertically (bowl down),
• with air flow in direction of arrow on body,
• upstream of regulators, lubricators, and cycling  
 valves,
• as close as possible to the air supply when  
  used as a main line filter,
• as close as possible to the device being  
  serviced when used as a final filter.
2. Before assembling the basic unit into the yoke  
  the port seal o-rings should be lightly 
  smeared with o-ring grease. 
3. Locate clamp ring under lugs on top of yoke,  
  offer basic unit into yoke with directional  

  arrows correctly aligned (an interference fit  
  prevents assembly if misaligned) before  
  engaging and fully tightening the clamp ring.
4. Turn bowl or bowl guard fully clockwise into  
  body before pressurizing. Lock symbols on  
  body and bowl guards must align.
5. Auto-drain units may be fitted with a short  
  drain pipe and connector, minimum 5 mm  
  bore, to the G1⁄8 bottom outlet.

A

B

C

 

Servicing

1. Open manual drain to expel accumulated 
   liquids. Keep liquids below baffle (53).
2. To operate automatic drain manually, lift  
  operating pin in bottom outlet with a blunt  
 rod. 
3. Clean or replace filter element when dirty.

Disassembly

1. Shut off inlet pressure. Reduce pressure in  
  inlet and outlet lines to zero. 
2. For ease of maintenance the unit can be re 
  moved from the yoke by unscrewing the  
  clamp ring, which will jack the unit out  
 downwards. 
3. Lift and turn the filter bow counterclockwise  
  and remove with bowl o-ring.
4. Disassemble in general accordance with  
  the item  numbers on exploded view. Do not  
  remove the drains or the service indicator 
   unless replacement is necessary. Remove  
  and replace only if they malfunction.

Cleaning

1. Partial cleaning of the filter element is possible 
   by washing the element in soapy water and   
  blowing out thoroughly with compressed air.   
  Replacement by a clean element is  
  recommended. Clean plastic bowl and lens  
  (45) with warm water only. Clean other parts  
  with warm water and soap.
2. Rinse and dry parts. Blow out internal  
  passages in body with clean, dry compressed  
 air.
3. Inspect parts. Replace those found to be  
  damaged. Replace plastic bowl with a metal  
  bowl if plastic bowl shows signs of cracking  
  or cloudiness.

Assembly

1. Lubricate o-rings with o-ring grease. 
2. Assemble the unit as shown on the exploded  
 view. 

3. Torque Table
                          Torque in
Item   

N-m    

(Inch-Pounds)

55 (Filter guide) 2,0 ... 2,7 max 

 (18 ... 25)

4.  Assemble baffle (53), c 1/4 turn.
5. Turn bowl or bowl with guard fully clockwise  
  into body.

Caution

Water vapor will pass through these units and 
could condense into liquid form downstream as 
air temperature drops. Install an air dryer if water 
condensation could have a detrimental effect on 
the application.

Technical features

Option selector

Port

2 1/4”

3 3/8“ 

4 1/2“ 

6 3/4

Option

Service indicator 

N None

Bowl

D Metal

Transparent with guard

Metal with Pyrex sight glass

Element

5 µm

25 µm

40 µm

Thread

PTF (1/8 PTF gauge ports)

ISO Rc taper (1/8 ISO Rc gauge ports)

ISO G parallel (1/8 ISO Rc gauge ports)

No thread (basic unit)

F64G – 

˙˙˙

 – 

˙˙˙

Drain

A Automatic

M Manual

Q  Manual 1/4 turn

55

56

8

7

6

2
4

3
5

1

48

32

47

18

31

30

29

43

44

46

45

40

36

38

37

41

42

39

33

35
34

26

22

24

23

27

28

25

19

21

20

54

53

Reviews: