Meaning of different parameters
Code Description
Values (bold = default)
Setting
compl.
P01
Complete cycle operating
mode
0: sequential
1: sequ timed close
2: semi-automatic
3: automatic
4: aut cell blocking
5: deadman's control (wire)
P02
Complete operating mode
automatic timed closing
0 to 30 (value x 10 s = time delay value)
2: 20 s
P03
Pedestrian cycle operating
mode
0: identical to complete cycle operating mode
1: without automatic closing
2: with automatic closing
P04
Short automatic closing time
delay in pedestrian cycle
0 to 30 ( value x 10 s = time delay value)
2: 20 s
P05
Long automatic closing time
delay in pedestrian cycle
0 to 99 ( value x 5 min = time delay value)
0: 0
P06
Pedestrian opening
amplitude
1: minimum pedestrian opening
9: maximum pedestrian opening
1: 80 cm
P07
Cell safety input
0: inactive
1
:
active
2: active with autotest via test output
3: active with autotest via power supply switching
4: bus cells
P08
Safety edge safety input
0: inactive
1: active
2: active with auto-test
P09
Programmable safety input
0: inactive
1
:
active
2: active with autotest via test output
3: active with autotest via power supply switching
P10
Programmable safety input
- function
0: active closing
1: active opening
2: active c ADMAP
3: all movement disabled
P11
Programmable safety input
- action
0: stop
1: stop + partial reversal
2: stop + complete reversal
P12
Orange warning light
0: no warning
1: with 2 s warning prior to movement
Code Description
Values (bold = default)
Setting
compl.
P13
Area lighting output
0: inactive
1: controlled operation
2: aut controlled operation
P14
Area lighting time delay
0 to 60 (value x 10 s = time delay value)
6: 60 s
P15
Auxiliary output
0: inactive
1: automatic: gate open indicator light
2: automatic: timed bistable
3: automatic: one-touch
4: controlled: bistable (ON-OFF)
5: controlled: one-touch
6: controlled: timed bistable
P16
Auxiliary output time delay
0 to 60 (value x 10 s = time delay value)
6: 60 s
P19
Closing speed
1: slowest speed to
10: highest speed -
Default value: 5
P20
Opening speed
1: slowest speed to
10: highest speed -
Default value: 5
P21
Closing slowdown zone
1: shortest slowdown zone
to
5: longest slowdown zone
Default value: 1
P22
Opening slowdown zone
1: shortest slowdown zone
to
5: longest slowdown zone
Default value: 1
P25
Closing torque limitation
1: minimum torque at
10: maximum torque
Adjusted when auto-programming complete
P26
Opening torque limitation
P27
Closing slowdown torque
limitation
P28
Opening slowdown torque
limitation
P33
Obstacle detection sensitivity 0: very low sensitivity
1: slightly sensitive
2: standard
3: very sensitive
P37
Wired control inputs
0: complete cycle mode - pedestrian cycle
1: opening mode - closing
P40
Coupling speed when closing 1: slowest speed to
4: fastest speed
Default value: 2
P41
Coupling speed when
opening
Operating code display
Code
Description
C1
Awaiting command
C2
Gate opening
C3
Awaiting gate closure
C4
Gate closing
C6
Detection in progress for cell safety
C7
Detection in progress for safety edge safety
C8
Detection in progress for programmable safety
C9
Detection in progress for emergency stop safety
C12
Reinjecting current
C13
Safety device autotest in progress
C14
Permanent complete opening wire control input
C15
Permanent pedestrian opening wire control input
C16
BUS cell programming refused
Cc1
9.6 V power supply
Cu1
24 V power supply
Fault and breakdown code display
Code
Description
Comments
Solution?
E1
Cell safety autotest fault
The cell autotest is not satisfactory.
Check that "
P07
LVFRUUHFWO\FRQ¿JXUHG&KHFNWKHZLULQJRIWKHFHOOV
E2
Programmable safety autotest fault
The programmable safety input autotest is not
satisfactory.
Check that "
P09
LVFRUUHFWO\FRQ¿JXUHG&KHFNWKHSURJUDPPDEOHVDIHW\LQSXWZLULQJ
E3
Defective safety edge autotest
The safety edge autotest is not satisfactory.
Check that "
P08
LVFRUUHFWO\FRQ¿JXUHG&KHFNWKHVDIHW\HGJHZLULQJ
E4
Obstacle detection when opening
E5
Obstacle detection when closing
E6
Cell safety fault
Detection in progress on safety input for longer than 3
minutes.
Check that no obstacles are causing the cells or safety edge to detect.
Check that "
P07
", "
P08
" or "
P09
LVFRUUHFWO\FRQ¿JXUHGLQUHODWLRQWRWKHGHYLFHFRQQHFWHGWRWKH
safety input.
Check the safety device wiring.
Check that the photoelectric cells are correctly aligned.
E7
Safety edge safety fault
E8
Programmable safety fault
E10
Motor short circuit protection
Check the motor wiring.
E11
24V power supply short protection
Product and additional devices connected to terminals
21 to 26 not operating
Check the wiring, then disconnect the power supply for 10 seconds.
E12
Hardware fault
The hardware autotests are not satisfactory
Repeat an order. If the fault is still present, contact Somfy.
E13
Accessories power supply fault
The accessories power supply cuts out following an
overload (excessive consumption)
N.B.: maximum accessories consumption = 1.2 A
Check the consumption of the connected accessories.
E15
Fault when the control box supplied by the
EDFNXSEDWWHU\LV¿UVWVZLWFKHGRQ
Disconnect the backup battery and connect the control box to the mains to switch it on for the
¿UVWWLPH
Access to memorised data
-
To access memorised data, select parameter
"
Ud
" and press "
OK
".
Data
Description
U0 to U1
Complete opening cycle counter
global [Hundred thousands - ten thousands - thousands] [hundreds - tens - units]
U2 to U3
since last self-learning [Hundred thousands - ten thousands - thousands] [hundreds - tens - units]
U6 to U7
Cycle counter with obstacle
detection
global [Hundred thousands - ten thousands - thousands] [hundreds - tens - units]
U8 to U9
since last self-learning [Hundred thousands - ten thousands - thousands] [hundreds - tens - units]
U12 to U13
Partial opening cycle counter
U14 to U15
Reset movement counter
U20
Number of remote controls memorised for complete opening control
U21
Number of remote controls memorised for pedestrian opening control
U22
Number of remote controls memorised for remote lighting control
U23
Number of remote controls memorised for auxiliary output control
U24
0 = no system key present, 1 = system key present
d0 to d9
Log of the last 10 faults (d0 most recent - d9 oldest)
dd
To clear the fault log: press and hold "
OK
" for 7 s.
Programming code display
Code
Description
H0
Awaiting setting
Hc1
Awaiting s 9.6 V power supply
Hu1
Awaiting s 24 V power supply
H1
Awaiting start of self-learning
H2
Self-learning mode - opening
H4
Self-learning mode - closing
F0
Awaiting remote control memorisation for operation in complete opening mode
F1
Awaiting remote control memorisation for operation in pedestrian opening mode
F2
Awaiting remote control memorisation for remote lighting control
F3
Awaiting remote control memorisation for auxiliary output control