7
Copyright © 2012 Somfy SAS. All rights reserved
EN
Elixo 500 3S io
Checks
Safety devices (cells, safety edge)
Check for correct operation every 6 months.
Backup battery
For optimum battery life, it is recommended that the main power supply be switched off and the motor operated using the battery for several cycles, three
times a year.
Replacing the battery in a Keygo io remote control (Fig. 19)
MAINTENANCE
TECHNICAL DATA
Power supply
230 V - 50
Max. power consumption
600 W (with 500 W remote lighting)
Climatic operating conditions
- 20°C/+ 60°C - IP 44
Somfy radio frequency
io 868 - 870 MHz
< 10 mW
Number of memorisable channels
1 W controls
(Keygo io, Situo io, etc.)
Complete/pedestrian opening control: 30
Lighting control: 4
Auxiliary output control: 4
2 W controls
(Keytis io, Telis io, Composio io,
etc.)
Unlimited
Remote lighting output
230 V - 500 W
19
C
R
2430
C
R
2430
1
2
Manual emergency unlocking (Fig. 17)
[1] Insert the key into the lock.
[2] Turn the key a quarter of a turn to the left.
[3] Turn the release handle to the right.
Do not forcibly push the gate. Hold the gate over its entire travel during manual
manoeuvres.
Locking the motorisation (Fig. 18)
[1] Turn the release handle to the left.
[2] Move the gate manually until the drive mechanism re-locks.
[3] Turn the key a quarter of a turn to the right.
[4] Remove the key
The motorisation must be locked before a new command.
18
17
[1]
[2]