GSM Auto Dialler

Model number 2G / 3G /4G - AD4IN1V4

PAGE 1

Summary of Contents for 2G

Page 1: ...2G 3G 4G GSM Auto Dialler Model number 2G 3G 4G AD4IN1V4 PAGE 1 ...

Page 2: ...ls all over Europe USA and Australia with excellent feedback The unit is enclosed in an IP65 rated enclosure meaning that it is perfectly weathered for outside installation and has passed testing in high heats and below freezing temperatures Specification GSM Frequency Quadband Frequency 850 900 1800 1900 2100mhz 4G Bands B1 B5 B7 B8 B12 B14 B18 B28 B25 B26 B28 B66 B71 Power Supply Voltage 9 24 vo...

Page 3: ...the simcard lines up with the clipped corner of the simcard holder as seen in the image above Signal Strength To help make sure that you place the unit in a suitable position you can text the unit to see how much signal strength the dialler is receiving by texting the command SIGNAL You will then receive a text message telling you the signal strength score between 0 up to 30 We strongly recommend ...

Page 4: ...r your contact numbers If you wish to cancel a number follow this example Example hash 1 2 3 4 or 5 equals DELETE hash 1 DELETE This deletes contact number 1 Dipswitch The dialler can work on 2G 3G 4G networks The module works worldwide with all simcards see page 3 for applicable bands You can choose which frequency the unit will use at the start by using the dipswitch combinations below 1 Dipswit...

Page 5: ...ssage Please Note You can only use a maximum of 19 character including spaces for your customised message Telephone Call Alerts The Auto Dialler can be programmed to send you a telephone call after each text alarm has been sent You will receive approximately three ring tones The unit will then hang up automatically This is to prevent call charges being incurred To set the call alert to ON please s...

Page 6: ...uk Alarm Input Input 4 only INPUT 4 can also be used as the alarm input where the input is not always live and it does not auto reset like inputs 1 3 The alarm is only made live by sending an SMS text message command This is useful for attaching things like PIR or Beam Sensors when you may only want them armed at night To activate this mode send the sms text command MODE 2 This sets the unit to al...

Page 7: ...EL This will Pulse the relay for 20 seconds Auto Relay Trigger Input On The Relay can be set to automatically pulse for 17 seconds when an input has been triggered Please be aware of any conflicts this may cause if you are already using relay 2 as an independently activated relay To turn this function on please send the text command AUTO ON This will turn the auto function on for relay on AUTO OFF...

Page 8: ...sor will pair the sensor to Input 1 Press the pairing button four times and trigger the sensor will pair the sensor to Input 4 LED 2 will flash when you press the pairing button LED 1 will flash when the paired sensor is active Page 8 www gsm activate co uk 01273462380 sales gsm activate co uk Wired Auto Dialler Inputs and Alarm The wired Auto Dialler inputs will still work and these will be share...

Page 9: ...ontacts which are capable of 8 Amp loads This is suitable for turning on or off electrical equipment Alternatively it can be used for resetting your alarm system The relay can be manually activated by text message commands or it can be set to pulse for 20 seconds when an input has been activated Please refer to page 6 NOTE For alarm panel installations please make sure you supply a 9 24 volts DC f...

Page 10: ...ical support please browse the FAQ s on our website www gsm activate co uk Alternatively you can email our technical support team at technical gsm activate co uk and we will do our best to reply within 24 hours Monday to Friday Page 10 30 12 21 GD ...