manualshive.com logo in svg
background image

GDO-6v3 

EasyRoller

®

Roll Up Garage Door Opener

INSTALLATION INSTRUCTIONS | OWNERS COPY

Featuring

TrioCode

Technology

Part # 13236 (Manual) v2.01

Содержание GDO-6v3 EasyRoller

Страница 1: ...GDO 6v3 EasyRoller Roll Up Garage Door Opener INSTALLATION INSTRUCTIONS OWNERS COPY Featuring TrioCode Technology Part 13236 Manual v2 01 ...

Страница 2: ... be lawfully excluded hereby expressly disclaims all conditions or warranties statutory or otherwise which may be implied by laws as conditions or warranties of purchase of an Automatic Technology Australia Pty Ltd Roll Up Door Opener Automatic Technology Australia Pty Ltd hereby further expressly excludes all or any liability for any injury damage cost expense or claim whatsoever suffered by any ...

Страница 3: ... Electric Beam 22 Auto Close 23 Final Setup 24 Setting of Courtesy Light Time 24 Setting the Pet Mode Position 24 Wall Transmitter Installation 24 Keyswitch Connection 24 Auxilary Output 25 Reset all Factory Defaults 25 SmartSolar Installation 26 Battery Backup Kit Installation 27 Parameters 28 Door Status Indicators 28 Button Functions 29 Default Settings Specifications 30 Troubleshooting 31 Maint...

Страница 4: ... NOT allow children to operate the EasyRoller Serious personal injury and or property damage can result from failure to follow this warning Photo Electric Beams must be installed where the closing force as measured on the bottom of the door is more than 400N 40kgf Regularly check to make sure that the Safety Obstruction Force is working correctly and is tested and set as per page 17 of this manual...

Страница 5: ...d electrical contractor Disconnect the power cord from mains power before making any repairs or removing covers Only experienced service personnel should remove covers from the opener When using Auto Close mode a photo electric beam must be fitted correctly and tested for operation at regular intervals Extreme caution is recommended when using Auto Close mode All safety rules must be followed In or...

Страница 6: ... position using mechanical parts such as cams and microswitches During installation the handheld transmitter can be programmed to set the door limits positions ISS intelligent safety obstruction system While the door is performing a close cycle should it hit an obstacle or be restricted in some manner it will automatically reverse The amount of force the door should encounter before reversing is a...

Страница 7: ...me You may also wish to open the door to a height suitable for pedestrian access Auto Close mode The opener can be programmed to automatically close after an open cycle The Auto Close time is adjustable It is compulsory to install a PE Beam if this mode is selected otherwise the door may cause personal injury or damage to property Photo Electric PE Beam optional The opener has an input to connect ...

Страница 8: ...adjust the Auto Close time Pressing the open button whilst pressing the Auto Close button increases length of operation Each press will increase the time by 5 seconds Pressing the close button will decrease the time FORCE MARGIN SET button The obstruction force margin is set automatically during installation The margin can be adjusted manually using the Force Margin Set button White Holding the Fo...

Страница 9: ...t be fitted for solar operation PROG INPUT is used to connect the Automatic Technology Handheld Programmer for editing control and receiver functions accessing diagnostic tools and activating special features and operating modes SBY 3 CONNECTOR is used to connect both Battery Backup Kits and SmartSolar kits 16 17 16 PWR PE PE GND OSC AUX ...

Страница 10: ...ead screw M4x50mm not included in some models 2 Nilock Hex nut M4 not included in some models 2 Flat washer I D 3 16 x 1 2 not included in some models 2 Spring washer I D 5 not included in some models 2 Locking bar covers 2 Weight bar not included in some models 1 Installation Instructions 1 TrioCode Keyring Transmitter Pack Weight Bar Drive Unit Locking Bar Covers ...

Страница 11: ...lions is not recommended IMPORTANT NOTE The opener should not be installed on any door incorporating a wicket door Position The opener can be installed on either the right or left hand side of the door when viewed from inside the garage The opener is factory set for right hand side installation This opener must be installed in a dry position that is protected from the weather Moisture or corrosion...

Страница 12: ...ly visible Choose the side where the opener will be installed ensuring there is sufficient sideroom Step 2 Fit the Weight Bar The weight bar must be fitted to the bottom centre for proper operation of the opener If the door has a handle Remove the door handle Fit the weight bar and refit the handle using the new fasteners provided Fig 04 If the door does not have a handle Locate the centre of the doo...

Страница 13: ... fitted check that the U bolt is tightened securely Open the door completely and tie safety ropes around the door roll approximately 300mm from each end Do not tie the ropes too tight as damage to the curtain may ensue At the end where the opener is to be fitted support the door with a ladder or suitable prop WARNING Make sure the support is snug under the door stable and will not move At the end wh...

Страница 14: ... the axle using the opener s saddle and U bolt as follows Using your reference marks as a guide sit the opener on the door mounting bracket and secure with the opener s U bolt and saddle and tighten firmly Adjust the door position if necessary on the brackets so that the door feeds smoothly into the guides Make sure that the centre of the door doesn t hit the lintel and that the curtain is not push...

Страница 15: ...n again to close the door Release the CLOSE button when the door is near the desired closed position Single presses of the CLOSE button will inch the door closed If the door overshoots press the OPEN button to move the door in the open direction When the door is at the desired close position press the SET button to record the close limit position The OPEN LIMIT LED will now flash Press and hold the...

Страница 16: ...th the close limit position press Button 2 to store this in memory PressButton1toopenthedoor Whenapproximately 2cm from the desired open position press and hold Button 3 for two seconds then release Each press of Button 1 will allow you to inch the door open Keep doing this until the door reaches the desired open limit position If the door is opened too far press Button 4 to inch the door towards ...

Страница 17: ...door Fig 15 Place a piece of timber approximately 40mm high on the floor directly under the door Fig 16 Press the OPERATE button to close door The door should strike the object and start to re open Step 8 2 Testing Open Cycle Press the OPERATE button to close the door Fig 15 Press again to open the door When the door reaches the half open point grab the bottom rail of the door firmly and the door sh...

Страница 18: ...the FORCE MARGIN SET button press the CLOSE button Each press decreases the force margin The CLOSE LIMIT LED will flash each time the CLOSE button is pressed to indicate a force margin decrease NOTE If the CLOSE LIMIT LED is lit continuously when pressing the CLOSE button this indicates that the minimum setting has been reached Test the force again as per Steps 8 1 and 8 2 Step 9 3 To Recall Factor...

Страница 19: ...ll beep four times on fourth press Fig 22 Press one of the four buttons on the transmitter for two 2 seconds pause for two 2 seconds then press the same button again for two 2 seconds Release the DOOR CODE button Press the transmitter button to test To change the default pet pedestrian door opening position refer to step 17 Step 10 4 Code a Transmitter Button to Enable Vacation Mode The opener can...

Страница 20: ...d without access to the opener s control panel as long as a pre coded transmitter is available IMPORTANT NOTE The door or courtesy light must activate when the steps below are performed This indicates that the pre coded transmitter is in range of the opener and the correct button has been pressed Take any pre coded transmitter Press the button for the function to be duplicated and release If the d...

Страница 21: ...ed Confirm this by pressing the transmitter button the function e g door opening should not respond Step 13 2 Deleting All Transmitter Codes Turn off power to the opener While switched off press and hold the DOOR CODE BUTTON Fig 27 Turn on the power to the opener while holding this button The OPEN LIMIT CLOSE LIMIT and DOOR STATUS LED s will illuminate for about five 5 seconds These LED s will turn ...

Страница 22: ... colour code red red red and gold on the PE Beams receiver between the V and NC terminals as shown in Fig 30 Alignment Power up the PE Beams The green LED on the transmitter and red LED on the receiver should turn ON to indicate power is present If the receiver is connected to power and the red LED is on while the green LED is on the transmitter and receiver are not aligned Make horizontal and or ...

Страница 23: ...ing the door it will re open and not Auto Close until the PE Beam s path is broken again Step 15 1 Setting Auto Close Time Hold down the AUTO CLOSE TIME button Fig 31 While holding in the AUTO CLOSE TIME button press the OPEN button each press will add one second to the Auto Close delay To decrease the delay time follow Step 15 1 a and press the CLOSE button each press will deduct one second from ...

Страница 24: ...e close position Pet Mode s active status is indicated by both the OPEN and CLOSE LIMIT LED s being illuminated If a Pet Mode button is pressed while the door is moving the door will stop If a Pet Mode button is pressed when the door is in the Pet position then the door will close Step 18 Installing the Wall Mounted Transmitter Optional Remove the faceplate from the transmitter Affix the baseplate ...

Страница 25: ...pulse for approximately 1 one second The maximum DC voltage must not exceed 35 volts DC Maximum current must not exceed 80 ma Fig 34 Step 21 Reset all Factory Defaults Turn power to the opener off Press and hold the SET Button Fig 35 Turn power on while holding the SET button Continue to hold until all LED s are off This will not erase transmitter codes stored in memory a b c d PWR AUX OUT OSC GND...

Страница 26: ...rtSolar Instruction Manual Feed the Solar Panel s cable through the black grommet on the chassis Connect the red wire to the Charger Board s SOLAR connector and the black wire to the SOLAR connector Fig 38 WARNING During Step 22 3 the opener will become active Step 22 3 Mount Connect the Battery Mount the Battery Box close to the opener Feed the 2 core 18awg gauge cable supplied through the Batter...

Страница 27: ...nd secure left side of battery kit with cable clamp a b c d e f g h i j WARNING After Step 23 1 k the opener may become active even when power is off This is a result of a residual charge in the batteries Connect battery harness together Fig 40 Reconnect power and re engage the motor Step 23 2 Testing the Battery Backup Kit Press either the OPERATE button or transmitter button to activate the door...

Страница 28: ... On Opening Flashing Closing Flashing Door travel stopped Flashing Flashing Door obstructed when opening Flashing Door obstructed when closing Flashing Beeps as door moves Opener overloaded Alternating flashes Alternating flashes Door in open position with Auto Close mode selected One second flashes Pet Mode engaged On On Mains power interrupted Rapid flashes ...

Страница 29: ...n OPEN Increases the Auto Close delay time AUTO CLOSE TIME then CLOSE Decreases the Auto Close delay time AUTO CLOSE TIME then SET Resets the factory default Auto Close delay time CLOSE for 6 secs Clears the door limits set positions Limits then need to be reset SET CLOSE for 2 secs Enters pet pedestrian position mode SET then power on hold until all LED s are off Deletes control parameters exclud...

Страница 30: ...el Receiver type TrioCode type Receiver code storage capacity 14 X 4 button Transmitter Codes Transmitter frequency TrioCode type Coding type Code hopping Number of code combinations Over 4 29 billion random codes Code generation Non linear encryption algorithm Courtesy light Festoon Type 15W 24VD C Controller fuse 10A slow blow NOTE 1 The door must be well balanced A person should be able to lift...

Страница 31: ...ll not close fully Door limits positions need to be reset Reset limits positions Step 7 3 page 16 Door will not open fully Door limits positions need to be reset Reset limits positions Step 7 3 page 16 Courtesy light not working Globe blown Replace globe Globe keeps blowing Incorrect globe type must be festoon Type 15W 24VD C globe Replace globe Auto Close not working PE Beam or wiring faulty PE B...

Страница 32: ...he door contacts a 40mm high object placed on the floor AS3350 NOTE If the door does not operate smoothly call your door professional Yearly Automatic Technology suggests you contact your door professional to perform an annual door service CAUTION Frequently examine door particularly cables springs and mountings for signs of wear damage or imbalance Do not use if repair or adjustment is needed sinc...

Страница 33: ...Owner Installation Instructions GDO 6v3 EasyRoller 33 Spare Parts ...

Страница 34: ...34 GDO 6v3 EasyRoller Owner Installation Instructions Notes ...

Страница 35: ...ence or failure to maintain the equipment in a proper working order as per clauses d through h k installation adjustment or use which is not in accordance with the instructions set out in installation instruction manual l attempted or complete modification or repairs to the product carried out by a person who is not authorised or has not been trained by ATA to carry out such modification or repairs ...

Страница 36: ...Technology Australia Pty Ltd No part of this document may be reproduced without prior permission In an ongoing commitment to product quality we reserve the right to change specification without notice E OE Automatic Technololgy Australia Pty Ltd ABN 11 007 125 368 6 8 Fiveways Boulevard Keysborough Victoria 3173 Australia P 1300 133 944 61 2 9722 5666 International Enquiries Only E sales ata aust c...

Отзывы: