24
5. BASIC OPERATION
(2) Target type icon
Selection of target type and configuration of prism constant correction value.
You can jump to the Distance config. or Reflector config. screen.
"19.2 Observation Conditions - Dist"
"19.3 Observation Conditions - Reflector (Target)"
: Prism (0 mm)
:
360° prism (-7 mm)
: Sheet (0 mm)
: N-Prism
: "+" indicates a target used with an external device or in a program installed
in the Program mode.
(3) Motor icon
Configuration of Auto Pointing/Auto Tracking status. The display may change slightly depending on the
target type selected. Auto Tracking items are only relevant to Auto Tracking models and are not available
for Auto Pointing models.
You can jump to the Search/Track config. screen.
"10.1 Auto Pointing and Auto Tracking Settings"
: Perform Auto Pointing and Tracking when measuring the distance
: Perform only Auto Pointing when measuring the distance
: Measure the distance only
: Start Auto Tracking. "TRK Off" is displayed when performing Auto
Tracking or when in "Prism wait" status. Tap to quit Auto Tracking.
: Begin searching
: Rotates the instrument 180°
One of the following icons will be displayed while the motor is in operation to indicate the current status of
the instrument.
: Rotating
: Rotating at fixed velocity
: Searching/Searching after target lost during Auto Tracking
: Auto Tracking in progress
: Auto Tracking idle (when Auto Tracking set)
: Auto Tracking in predicted direction
: Waiting for prism during Auto Tracking
Predicted direction and waiting for prism: "10.1 Auto Pointing and Auto Tracking Settings
• Auto Tracking and Auto Pointing cannot be performed when "Reflectorless" has been selected as the
target type (
will be displayed). Auto Tracking cannot be performed when "Sheet" has been selected
as the target type (
will be displayed).
• An arrow indicating turn direction will be displayed when the instrument is rotating at a fixed velocity.