15. SETTING-OUT MEASUREMENT
PROCEDURE
1. Select "Setting out" in <Menu> to display <Setting
out>.
2. Set the instrument station and the backsight
station to define the reference direction. Select
"Occupy setup" in <Setting out>. Enter data for
the instrument station and press
[OK]
to move to
Backsight setup.
"13.1 Entering Instrument Station Data"
3. Set the azimuth angle for the backsight station.
Press
[OK]
to return to <Setting out>.
4. Select "SO data setting" in <Setting out>.
In the distance mode that conforms to your
measurement requirements, enter the included
angle between the reference point and the setting-
out point in "SO.H.ang", and the distance (slope
distance, horizontal distance or height difference)
from the instrument station to the position to be set
out in "SO.Sdist". Press
[OK]
to set the input
values.