88
15. SETTING-OUT MEASUREMENT
• Each time
[Shvr]
is pressed, the distance mode
changes from "SD" (slope distance), "HD"
(horizontal distance), "VD" (height difference),
and "Ht." (REM).
• Press
[COORD]
and input coordinates in <Key in
coord>. The angle and distance from these
coordinates to the position to be set out will be
calculated.
5. Press
[H.TURN]
to automatically rotate the
instrument until the difference in horizontal angle
to the setting out point reads 0
°
.
• Switch the Operating icons and press
[CNFG]
to
set setting out accuracy. When the position of the
target is within this range both arrows will be
displayed to indicate that the target position is
correct.
6. Position the target on the line of sight and press
[MEAS]
to begin distance measurement.
The distance and direction to move the target until
the setting out point is located is displayed on the
instrument. The sighting point measurement
results (currently installed position of the target)
are displayed.
• Movement indicator (Red indicates that target
position is correct)
: (Viewed from instrument) Move
target to the left
: (Viewed from instrument) Move
target to the right
: Target position is correct
: (Viewed from instrument) Move
target closer
: (Viewed from instrument) Move
target away
: (Viewed from instrument) Target
position is correct
Arrows indicate direction to move