Smiths Medical International Ltd.
Issue 5 (August 2004)
3200 Service Manual
Page v
CHAPTER 3
FUNCTIONAL DESCRIPTIONS
Introduction
................................................................................................... 3-1
Drive system
.................................................................................................. 3-1
Introduction ........................................................................................... 3-1
Stepper motor and leadscrew ................................................................ 3-1
Microcomputer ....................................................................................... 3-1
Toggle mechanism ................................................................................. 3-1
Plunger clamp ....................................................................................... 3-2
Internal occlusion system
............................................................................. 3-2
In-line occlusion system
............................................................................... 3-2
Electro/mech control system
........................................................................ 3-3
Sensing (alarm) systems
............................................................................... 3-3
Introduction ........................................................................................... 3-3
End of infusion ...................................................................................... 3-3
Syringe nearly empty ............................................................................. 3-3
AC power failure .................................................................................... 3-3
Battery voltage low ................................................................................ 3-4
Self tests/pump malfunction .................................................................. 3-4
Drive disengaged or syringe not fitted .................................................... 3-4
Syringe sizing system ........................................................................... 3-4
Rate setting ........................................................................................... 3-4
Cannot zero extension set ..................................................................... 3-5
Cannot calibrate extension set .............................................................. 3-5
Communications (RS232) failure ............................................................ 3-5
Software
.................................................................................................... 3-5
Self tests ............................................................................................... 3-5
Design ................................................................................................... 3-5
CHAPTER 4
CIRCUIT DESCRIPTIONS
Introduction
................................................................................................... 4-1
Main board
................................................................................................... 4-1
Processor core ...................................................................................... 4-1
Motor interface ...................................................................................... 4-3
Power control ......................................................................................... 4-3
Sensors interface .................................................................................. 4-4
RS232 serial interface ........................................................................... 4-5
Umbilical connector ............................................................................... 4-5
Input/output serial interface ................................................................... 4-5
(contd.)
Contents
Summary of Contents for Graseby 3200
Page 15: ...CHAPTER 1 INTRODUCTION FEATURES and SPECIFICATION 3200 In line Pressure Syringe Pump ...
Page 22: ...CHAPTER 2 CONFIGURATION DIAGNOSTICS and OCCLUSION THRUST 3200 In line Pressure Syringe Pump ...
Page 37: ...CHAPTER 3 FUNCTIONAL DESCRIPTIONS 3200 In line Pressure Syringe Pump ...
Page 43: ...CHAPTER 4 CIRCUIT DESCRIPTIONS 3200 In line Pressure Syringe Pump ...
Page 83: ...CHAPTER 6 FUNCTIONAL TESTS and MANUFACTURNG SETTINGS 3200 In line Pressure Syringe Pump ...
Page 91: ...CHAPTER 7 ILLUSTRATED PARTS LIST 3200 In line Pressure Syringe Pump ...
Page 105: ...CHAPTER 8 BRAUN PERFUSOR CONVERSION 3200 In line Pressure Syringe Pump ...
Page 108: ...CHAPTER 9 DC INPUT VERSION of 3200 3200 In line Pressure Syringe Pump ...
Page 111: ...APPENDIX FITTING a MODIFIED SIZE SENSOR FLAG 3200 In line Pressure Syringe Pump ...