Smiths Medical International Ltd.
Issue 5 (August 2004)
3200 Service Manual
4 — 19
Input/output serial interface
D21
GREEN
D20
GREEN
DCSW
D19
GREEN
D18
GREEN
D17
GREEN
4
1
5
1
3
1
VCC
2
1
R70A
100K*
KEYBOARD
GND
1 2 3 4 5 6 7 8 9
1
0
P
L
3
H
EADER 10
VDD
C29
100n
F
VCC
GND
R59
10K
VCC
MOS
I
SC
L
K
F
PSE
L
1
QA
'
8
A/QA
7
B/QB
13
C/QC
6
D/QD
14
E/QE
5
F
/Q
F
15
G/QG
4
H
/Q
H
16
Q
H'
17
G1
2
G2
3
S0
1
S1
19
C
L
K
12
C
L
R
9
SR
11
S
L
18
I
C8
74
H
C299
GND
3 X BA
T
85
D11
D12
D13
5
6
R66C
1K
#
3
4
R66B
1K
#
1
2
R66A
1K
#
R42
560R
R43
560R
R44
560R
Q9
BC184
L
Q10
BC184
L
Q11
BC184
L
R45
560R
R46
560R
Q12
BC184
L
Q13
BC184
L
POWER ON
OP
T
O_C
TL
[0
..
2
]
GND
7
8
R66D
1K
#
1
2
R50A
1K
#
3
4
R50B
1K
#
5
6
R50C
1K
#
7
8
R50D
1K
#
OP
T
O_C
TL
[0
..
2
]
QA
'
8
A/QA
7
B/QB
13
C/QC
6
D/QD
14
E/QE
5
F
/Q
F
15
G/QG
4
H
/Q
H
16
Q
H'
17
G1
2
G2
3
S0
1
S1
19
C
L
K
12
C
L
R
9
SR
11
S
L
18
I
C9
74
H
C299
GND
OP
T
O_C
TL
0
OP
T
O_C
TL
1
OP
T
O_C
TL
2
R52
560R
R56
10K
R57
10K
D14
RED
R53
560R
R54
560R
R55
10K
DCSW
D15
GREEN
D16
AMBER
1
2
R73A
1K
#
5
6
R73C
1K
#
1
2
R74A
1K
#
5
6
R74C
1K
#
3
4
R73B
1K
#
7
8
R73D
1K
#
3
4
R74B
1K
#
7
8
R74D
1K
#
VCC
SER
1
A
2
B
3
C
4
D
5
E
10
F
11
G
12
H
14
Q
H
13
C
L
K
7
I
N
H
6
S
H
/
L
D
15
C
L
R
9
I
C11
74
H
C166
M
I
SO
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
P
L
5
H
EADER 16
V
F
D_BUSY
R51
10K
V
F
DPWR
GND
D22
6
v
2
D23
6
v
2
D24
6
v
2
D25
6
v
2
GND
Q15
BC184
L
Q16
BC184
L
GND
Q14
BC184
L
C28
100n
F
VCC
GND
V
F
DS
T
B
F
PSE
L
2
R40
6K8
VCC
DCSW
VCC
QA
'
8
A/QA
7
B/QB
13
C/QC
6
D/QD
14
E/QE
5
F
/Q
F
15
G/QG
4
H
/Q
H
16
Q
H'
17
G1
2
G2
3
S0
1
S1
19
C
L
K
12
C
L
R
9
SR
11
S
L
18
I
C10
74
H
C299
1
2
R47A
1K
#
3
4
R47B
1K
#
7
8
R47D
1K
#
1
2
R48A
1K
#
7
8
R48D
1K
#
GND
V
F
D MODU
L
E
5
6
R47C
1K
#
3
4
R48B
1K
#
5
6
R48C
1K
#
GND
Q2
BC184
L
C2
100n
F
R10
10K
R76
10K
VCC
VAC
1 2
P
L
2
H
EADER 2
R38
330R
R39
910R
Q8
BC184
L
C30
100n
F
R41
4K7
SOUND
ENAB
L
E_MO
T
OR
D28
1N4448
GM037
9-
A
GND
SOUNDER
R3
10K
GND
Figure 4.10 Input/output serial interface circuit diagram
Summary of Contents for Graseby 3200
Page 15: ...CHAPTER 1 INTRODUCTION FEATURES and SPECIFICATION 3200 In line Pressure Syringe Pump ...
Page 22: ...CHAPTER 2 CONFIGURATION DIAGNOSTICS and OCCLUSION THRUST 3200 In line Pressure Syringe Pump ...
Page 37: ...CHAPTER 3 FUNCTIONAL DESCRIPTIONS 3200 In line Pressure Syringe Pump ...
Page 43: ...CHAPTER 4 CIRCUIT DESCRIPTIONS 3200 In line Pressure Syringe Pump ...
Page 83: ...CHAPTER 6 FUNCTIONAL TESTS and MANUFACTURNG SETTINGS 3200 In line Pressure Syringe Pump ...
Page 91: ...CHAPTER 7 ILLUSTRATED PARTS LIST 3200 In line Pressure Syringe Pump ...
Page 105: ...CHAPTER 8 BRAUN PERFUSOR CONVERSION 3200 In line Pressure Syringe Pump ...
Page 108: ...CHAPTER 9 DC INPUT VERSION of 3200 3200 In line Pressure Syringe Pump ...
Page 111: ...APPENDIX FITTING a MODIFIED SIZE SENSOR FLAG 3200 In line Pressure Syringe Pump ...