Smiths Medical International Ltd.
Issue 5 (August 2004)
3200 Service Manual
4 — 9
Syringe size and status sensors
The syringe size sensors board is physically located at the centre of the lower casing. The
circuit diagram for these sensors is shown in
Figure 4.14
. The layout of the components
are shown in
Figure 7.6
.
Syringe size
sensors
The status sensors board is physically located on the left hand side of the lower casing.
The circuit diagram for these sensors is shown in
Figure 4.15
. The layout of the
components are shown in
Figure 7.5
.
Status
sensors
The Distribution board routes data between each individual board and also to the umbilical
cable that connects to the Main board.
The Distribution board sits on a tray. The board and tray are situated in the lower casing of the
pump. There are seven plugs situated on the board - PL1 to PL7.
The wiring to the plugs is shown in
Figure 4.16
and the layout of the connectors on the board
in
Figure 7.10
.
The ACAM pressure sensing board is situated in the concaved housing that is fixed to the
extreme left hand side of the pump. A six-way connector is used to route the signals to
the Distribution board.
The ACAM pressure sensing circuit is shown in
Figure 4.17
.
Pressure
sensing board
The Main board is fixed to the pump’s top casing and the components attached to the
board are shown in
Figure 7.7
.
Main board
components
The Regulator board is located on the right hand side of the lower casing and consists of a
fused primary switching power supply. The component layout diagram is shown in
Figure
7.8
.
Regulator
board
components
The eleven buttons and the associated connections that make up the front membrane
switch panel are shown in
Figure 4.18
.
Membrane
switch panel
The ribbon cable connections to the RS232 D connector are shown in
Figure 4.19
.
‘D’ connector
Distribution
board
Summary of Contents for Graseby 3200
Page 15: ...CHAPTER 1 INTRODUCTION FEATURES and SPECIFICATION 3200 In line Pressure Syringe Pump ...
Page 22: ...CHAPTER 2 CONFIGURATION DIAGNOSTICS and OCCLUSION THRUST 3200 In line Pressure Syringe Pump ...
Page 37: ...CHAPTER 3 FUNCTIONAL DESCRIPTIONS 3200 In line Pressure Syringe Pump ...
Page 43: ...CHAPTER 4 CIRCUIT DESCRIPTIONS 3200 In line Pressure Syringe Pump ...
Page 83: ...CHAPTER 6 FUNCTIONAL TESTS and MANUFACTURNG SETTINGS 3200 In line Pressure Syringe Pump ...
Page 91: ...CHAPTER 7 ILLUSTRATED PARTS LIST 3200 In line Pressure Syringe Pump ...
Page 105: ...CHAPTER 8 BRAUN PERFUSOR CONVERSION 3200 In line Pressure Syringe Pump ...
Page 108: ...CHAPTER 9 DC INPUT VERSION of 3200 3200 In line Pressure Syringe Pump ...
Page 111: ...APPENDIX FITTING a MODIFIED SIZE SENSOR FLAG 3200 In line Pressure Syringe Pump ...