09/08
Operating Instructions ACU
247
Actual value memory
No.
Description
Unit
Setting range
Chapter
237 Reset memory
- Selection
18.3
Controlled commissioning
369 Motor Type
- Selection
7.2.3
Rated Motor Parameters
370 Rated voltage
V
0.17
⋅
U
FUN
... 2
⋅
U
FUN
9.1
371 Rated current
A
0.01
⋅
I
FUN
... 10
⋅
ü
⋅
I
FUN
9.1
372 Rated speed
U/min 96 ... 60000
9.1
373 No. of pole pairs
-
1 ... 24
9.1
374 Rated cosine Phi
-
0.01 ... 1.00
9.1
375 Rated frequency
Hz
10.00 ... 1000.00
9.1
376 Rated mech. power
kW
0.1
⋅
P
FUN
... 10
⋅
P
FUN
9.1
Further motor parameters
377 Stator Resistance
mOhm 0 ... 65535
9.2.1
378 Leakage Coefficient
%
1.0 ... 20.0
9.2.2
383 Voltage constant
mVmin 0.0 … 850.0
9.2.5
384 Stator Inductance
mH
0.1 … 500.0
9.2.6
System Data
389 Factor Actual Value System
-
-100.000 ... 100.000
10.1
397 Nominal volumetric flow
m3/h 1 ... 99999
10.2
398 Nominal pressure
kPa
0.1 ... 999.9
10.2
Pulse Width Modulation
400 Switching frequency
- Selection
17.1
401 Min. switching frequency
- Selection
17.1
Error/warning behavior
405 Warning limit, short-term Ixt
%
6 ... 100
12.1
406 Warning limit long-term Ixt
%
6 ... 100
12.1
407 Warning Limit Heat Sink Temp
deg.C -25 ... 0
12.2
408 Warning Limit Inside Temp.
deg.C -25 ... 0
12.2
409
Controller
status
message
- Selection
12.3
Bus controller
412 Local/Remote
- Selection
17.3
Error/warning behavior
415 IDC Compensation Limit
V
0.0 ... 1.5
12.4
417 Frequency Switch-Off Limit
Hz
0.00 ... 999.99
12.5
Frequency Limits
418 Minimum Frequency
Hz
0.00 ... 999.99
13.1
419 Maximum Frequency
Hz
0.00 ... 999.99
13.1
Frequency ramps
420 Acceleration (clockwise)
Hz/s
0.00 ... 9999.99
13.7
421 Deceleration (clockwise)
Hz/s
0.01 ... 9999.99
13.7
422 Acceleration anticlockwise
Hz/s
-0.01 ... 9999.99
13.7
423 Deceleration anticlockwise
Hz/s
-0.01 ... 9999.99
13.7
424 Emergency stop clockwise
Hz/s
0.01 ... 9999.99
13.7
425 Emergency stop anti-clockwise
Hz/s
0.01 ... 9999.99
13.7
426 Maximum leading
Hz
0.01 ... 999.99
13.7
430 Ramp rise time clockwise
ms
0 ... 65000
13.7
431 Ramp fall time clockwise
ms
0 ... 65000
13.7
432 Ramp rise time anticlockwise
ms
0 ... 65000
13.7
433 Ramp rise time anticlockwise
ms
0 ... 65000
13.7
Operating Instructions ACU
247
09/08
Summary of Contents for Bonfiglioli Vectron ACTIVE CUBE ACU 201 Series