AND connection, positive edge
Parameter
Operation Mode Timer 1
790 or
Operation Mode Timer 2
793 = 3
Input
Output
Time 2
Time 1
Time 1 Time 1
Time 2
1)
2)
3)
4)
5)
1) As soon as the positive signal edge is received at the input, time 1 (signal delay)
is started.
2) If a positive signal edge is detected within time 1 (signal delay), time 1 starts
again (retrigger).
3) After the expiry of time 1 (signal delay), the output signal is switched on for the
time 2 (signal duration).
4) Within the time 2 (signal duration), the output is switched off by the input signal
(AND-connection).
5) If the input signal is present during the whole time 2 (signal duration), the output
signal remains on in this time.
: Time not run out completely
: Time run out completely
Factory settings: Time 1= 0, Time 2 = 0
Input
Output
In the factory settings the ouput signal follows the input signal.