252
Operating Instructions ACU
09/08
Current Controller
No.
Description
Unit Setting
range Chapter
700 Amplification
-
0.00 ... 2.00
16.5.1
701 Integral time
ms
0.00 ... 10.00
16.5.1
Further motor parameters
713 Magnetizing current 50% flux
%
1 ... 50
9.2.3
714 Magnetizing current 80% flux
%
1 ... 80
9.2.3
715 Magnetizing current 110% flux
%
110 ... 197
9.2.3
716 Rated magnetizing current
A 0.01
⋅
I
FUN
... ü
⋅
I
FUN
9.2.3
Field Controller
717 Reference Flux
%
0.01 ... 300.00
16.5.5
Further motor parameters
718 Rated slip correction factor
%
0.01 ... 300.00
9.2.4
Frequency Limits
719 Slip Frequency
%
0 ... 10000
13.2
Speed controller
720 Operation mode
- Selection
16.5.3
721 Amplification 1
-
0.00 ... 200.00
16.5.3
722 Integral time 1
ms
0 ... 60000
16.5.3
723 Amplification 2
-
0.00 ... 200.00
16.5.3
724 Integral time 2
ms
0 ... 60000
16.5.3
Acceleration Pre-Control
725 Operation mode
- Selection
16.5.4
726 Minimum acceleration
Hz/s
0.1 ... 6500.0
16.5.4
727 Mech. time constant
ms
1 ... 60000
16.5.4
Speed controller
728 Current Limit
A
0.0 ... ü
⋅
I
FUN
16.5.3.1
729 Current limit generator operation
A
-0.1 ... ü
⋅
I
FUN
16.5.3.1
730 Torque limit
%
0.00 ... 650.00
16.5.3.1
731 Torque limit generator operation
%
0.00 ... 650.00
16.5.3.1
732 P comp. torque upper limit
%
0.00 ... 650.00
16.5.3.1
733 P comp. torque lower limit
%
0.00 ... 650.00
16.5.3.1
Speed controller
734 Isq limit source motor operation
-
Selection
16.5.3.2
735 Isq limit source gen. operation
-
Selection
16.5.3.2
736 Torque limit source motor operation
-
Selection
16.5.3.2
737 Torque limit source gen. operation
-
Selection
16.5.3.2
738 Speed control switch-over limit
Hz
0.00 ... 999.99
16.5.3
739 Power Limit
kW
0.00 ... 2
⋅
ü
⋅
P
FUN
16.5.3.1
740 Power limit generator operation
kW
0.00 ... 2
⋅
ü
⋅
P
FUN
16.5.3.1
Field Controller
741 Amplification
-
0.0 ... 100.0
16.5.5
742 Integral time
ms
0.0 ... 1000.0
16.5.5
743 Ref. Isd upper limit
A 0.1
⋅
I
FUN
... ü
⋅
I
FUN
16.5.5.1
744 Ref. Isd lower limit
A -I
FUN
... I
FUN
16.5.5.1
Speed controller
748 Backlash damping
%
0 ... 300
16.5.3
Modulation Controller
750 Reference modulator
%
3.00 ... 105.00
16.5.6
752 Integral time
ms
0.0 ... 1000.00
16.5.6