09/08
Operating Instructions ACU
79
The CTRL menu branch can be accessed via the navigation
within the menu structure. The CtrL function contains sub-
functions which are displayed according to the operating point
of the frequency inverter.
Pressing the RUN key leads to a direct change from anywhere
within the menu structure to the motorpoti function Pot
F
for
clockwise rotation or Potr for anticlockwise rotation.
If the drive is already running, the display reads int
F
(forward,
clockwise) / intr (reverse, anticlockwise) for the function in-
ternal reference value or inP
F
(forward, clockwise) / inPr
(reverse, anticlockwise) for the function „Motorpoti (KP)“.
The function „Motorpoti (KP)“ enables linking to other refer-
ence sources in the reference frequency channel. The function
is described in chapter „Reference values, Motorpoti (KP)“.
Motor potentiometer function Pot
Using the arrow keys, you can adjust the output frequency of
the frequency inverter from the
minimum frequency
418 to
the
maximum frequency
419. The acceleration corresponds to
the factory setting (2 Hz/s) for the parameter
Ramp Keypad-
Motorpoti
473. The parameters
Acceleration (clockwise)
420
and
Deceleration (clockwise)
421 are taken into account with
lower acceleration figures.
Internal reference value int
The drive is in operation, i.e. output signals are present at the
frequency inverter and the current actual value is displayed.
Press an arrow key to switch to the motor potentiometer func-
tion Pot. The current frequency value is taken over in the mo-
tor potentiometer function Pot.
Function
Motorpoti (KP) inP
Using the arrow keys, you can adjust the output frequency of
the frequency inverter from
Minimum frequency
418 to
Max-
imum frequency
419. The frequency value adjusted via the
control unit can be linked to other reference values via the
Reference frequency source
475 (Chapter „Reference frequen-
cy source“ and „Motorpoti (KP)“).
JOG frequency JOG
This function is useful for manual setup and positioning of a
machine. The frequency of the output signal is set to the en-
tered value if the FUN key is pressed.
•
Press FUN key to switch from the internal reference value
int or the motor potentiometer function Pot to parameter
JOG frequency
489.
•
While keeping the FUN key pressed, press the arrow keys
to adjust the required frequency.
•
(The frequency value last adjusted is saved as the
JOG
frequency
489.)
•
Release the FUN key to stop the drive.
•
(The display returns to the previous function Pot or int. or
inP if function „Motorpoti (KP)“ is activated).