09/08
Operating Instructions ACU
157
14.2.1.1 Output Characteristic
The voltage range of the output signal at multifunction output 1 can be adjusted. The
value range of the actual value selected via parameter
Analog operation
553
is
assigned to the value range of the output signal which is adjusted via the parameters
Voltage 100%
551
and
Voltage 0%
552.
Parameter
Settings
No.
Description
Min.
Max.
Fact. sett.
551 Voltage 100%
0.0 V
22.0 V
10.0 V
552 Voltage 0%
0.0 V
22.0 V
0.0 V
Analog Operation
553
with abs. act.
value:
Analog operation
553
with signs:
0V
+10V
+24V
50%
0%
100%
0V
+5V
+24V
0%
-100%
100%
+10V
With the parameters
Voltage 100%
551
and
Voltage 0%
552, the voltage range at
100% and 0% of the output parameter is set. If the output value exceeds the refer-
ence value, the output voltage also exceeds the value of the parameter
Voltage
100%
551
up to the maximum value of 24V.
14.2.2 Frequency Output MFO1F
The multifunctional output MFO1 can be used as a frequency output in the setting of
Operation Mode
550 =
“3 - Repetition Frequency”. The DC 24V output signal is as-
signed to the abs. value of the speed or frequency via the parameter
Repetition
Freq. Operation
555
. The selection of the operation modes depends on the exten-
sion modules installed as an option.
Repetition Freq. Operation
555
Function
0 - Off
Repetition frequency operation MFO1 switched off
1 - Actual Frequency
Abs. value of the
Actual frequency
241.
2 - Stator Frequency
Abs. value of the
Stator frequency
210
.
3 - Frequency Speed Sensor 1 Abs. value of the
Encoder 1 Frequency
217.
5 - Repetition Frequency Input Abs. value of the
Repetition freq. input
252
.
14.2.2.1 Scaling
The repetition frequency mode for the multifunction output corresponds to the map-
ping of an incremental sensor. The parameter
Division marks
556 must be parame-
terized according to the frequency to be output.
Parameter
Settings
No.
Description
Min.
Max.
Fact. sett.
556
Division Marks
30 8192 1024
The frequency limit of f
max
=150 kHz may not be exceeded in the calculation of the
parameter
Division marks
556.
value
Frequency
Hz
150000
S
max
=
Operating Instructions ACU