Parameter List
The parameter list is structured according to the menu branches of the control unit.
The parameters are listed in ascending numerical order. A headline (shaded) can
appear several times, i.e. a subject area may be listed at different places in the table.
For better clarity, the parameters have been marked with pictograms:
The parameter is available in the four data sets.
The parameter value is set by the SETUP routine.
This parameter cannot be written when the frequency inverter is in operation.
I
FUN,
U
FUN,
P
FUN
:
rated values of the frequency inverter, ü: overload capacity of frequency inverter
(201) value for ACU201 devices
(401) value for ACU401 devices
ACU201 devices: U
dmax
=387,5 V, ACU401 devices: U
dmax
=770 V
Note:
At the control unit KP500 parameter numbers > 999 are displayed hexade-
cimal at the leading digit (999, A00 … B5 … C66).
21.1
Actual Value Menu (VAL)
Actual Values of the Machine
No.
Description
Unit
Display range
Chapter
210 Stator Frequency
Hz
0.00 ... 999.99
18.2
211 R.m.s Current
A
0.0 ... I
max
18.2
212 Output Voltage
V
0.0 ... U
FUN
18.2
213 Active Power
kW
0.0 ... P
max
18.2
214 Active Current
A
0.0 ... I
max
18.2
215 Isd
A
0.0 ... I
max
18.2
216 Isq
A
0.0 ... I
max
18.2
217 Encoder 1 Frequency
Hz
0.00 ... 999.99
18.2
218 Encoder 1 Speed
1/min 0 ... 60000
18.2
221 Slip Frequency
Hz
0.0 ... 999.99
18.2
Actual Values of the Frequency Inverter
222 DC-Link Voltage
V
0.0 ... U
dmax
-25
18.1
223 Modulation
%
0 ... 100
18.1
Actual Values of the Machine
224
Torque
Nm
±
9999.9
18.2
225 Rotor Flux
%
0 ... 100
18.2
226 Winding Temperature
deg.C 0 ... 999
18.2
227 Act. Rotor Time Constant
ms
0 ...
τ
max
18.2
Actual Values of the Frequency Inverter
228 Internal ref. frequency
Hz
0.00 ... f
max
18.1
229
Reference percentage %
±
300.00
18.1
230 Actual percentage value
%
±
300.00
18.1
Actual value memory
231 Peak value long-term Ixt
%
0.00 ... 100.00
18.3
232 Peak value short-term Ixt
%
0.00 ... 100.00
18.3
Actual Values of the Machine
235 Flux-forming voltage
V
0.0 ... U
FUN
18.2
236 Torque-forming voltage
V
0.0 ... U
FUN
18.2
238 Flux value
%
0.0 ... 100.0
18.2
239 Reactive current
A
0.0 ... I
max
18.2
240 Actual speed
1/min 0 ... 60000
18.2
241 Actual frequency
Hz
0.0 ... 999.99
18.2
Operating Instructions ACU