
CONFIGURATION
TRP9250 has a pre-programmed Configuration PROM containing the necessary parameters to
control the function of the equipment. Some of these parameters are also contained in the
non-volatile memory and may therefore be changed by simple programming via the keyboard to
suit the individual user.
As the non-volatile memory has battery back-up, all changes in the configuration together with other
user-programmable functions and channels will be preserved with a good back-up battery.
To change the configuration of a function, select Configuration Mode and enter the number of the
function in question. Some functions requires only to be selected by their number to execute the
change, but most functions has several parameters with values which must be changed and stored
with the "STO" key to store the change.
To prevent unauthorized programming of the configuration, the Configuration Mode may be
protected with a Password. As default the Password is equal to 0 which requires no confirmation
when selecting Configuration Mode. The Password may be changed by selecting Function Number
99 in the Configuration Mode. Next time Configuration Mode is selected the correct Password must
be entered to get access to the mode. Passwords from 1 to 9999999 may be used.
Select Configuration Mode
Press
If no Password has been programmed ( Password = 0 ) the transceiver is ready for changing
configurable functions.
If a Password has been programmed ( Password: 1 - 9999999 ) it is necessary to enter the correct
Password to get access to the Configuration Mode.
Press
"Password"
Reconfiguration of a Function with Parameters
To make a reconfiguration of a Function with parameters enter the number of the Function in the
Transmitter Display.
Press
"Function No."
The current corresponding parameters are displayed in the Receiver Display with a flashing bar
below the first parameter to be changed.
CONFIGURATION
INSTALLATION
TRP 9250 TECHNICAL MANUAL
3-49
Summary of Contents for TRP 9250
Page 1: ...TRP 9250 250 Watt Radio Transceiver for MF HF SKANTI...
Page 5: ...ff qom VORM qb ekf i j kr i...
Page 7: ...INTRODUCTION 1 2 TRP 9250 TECHNICAL MANUAL...
Page 17: ...OPERATION 2 OPERATION Table of Contents 2 2 TRP 9250 TECHNICAL MANUAL...
Page 73: ...INSTALLATION 3 INSTALLATION Table of contents 3 2 TRP 9250 TECHNICAL MANUAL...
Page 99: ...INSTALLATION 3 28 TRP 9250 TECHNICAL MANUAL...
Page 139: ...TECHNICAL DESCRIPTION 4 TECHNICAL DESCRIPTION Table of Contents 4 2 TRP 9250 TECHNICAL MANUAL...
Page 147: ......
Page 149: ......
Page 150: ......
Page 152: ...SERVICE 5 SERVICE Table of contents 5 2 TRP 9250 TECHNICAL MANUAL...
Page 166: ...SERVICE POWER PROTECTION 5 16 TRP 9250 TECHNICAL MANUAL...
Page 174: ...SERVICE SERVICE RELATED PROG KEY OPERATIONS 5 24 TRP 9250 TECHNICAL MANUAL...
Page 194: ...DSC 9000 FRONT PANEL DSC OPERATION DSC 9000 FRONT PANEL 6 2 TRP 9250 TECHNICAL MANUAL...
Page 264: ...DSC OPERATION 6 72 TRP 9250 TECHNICAL MANUAL...
Page 266: ...DSC INSTALLATION 7 DSC INSTALLATION Table of Contents 7 2 TRP 9250 TECHNICAL MANUAL...
Page 288: ...DSC INSTALLATION 7 24 TRP 9250 TECHNICAL MANUAL...