6.14.3 Escape&Return function
SmartHandles with Escape&Return function allow opening without the
need to press an identification medium again, shortly after the door was
closed.
The function is activated by selecting the corresponding check box and the
specification of a time window in the integrator system. It must then be
programmed with the SmartIntego tool.
NOTE
Escape & Return: Legal situation
The Escape & Return Timeout can be between 30 s and 240 s (WO) re-
spectively 1 s and 240 s (SVCN). The use and configuration of Escape &
Return may be subject to legal regulations (e.g. Norway).
Inform yourself in advance about legal regulations.
A sensor in the SmartHandle detects that the inside handle has been
operated. The SmartHandle then engages for an adjustable time and
signals this visually and acoustically.
Disengagement takes place after the previously defined time. The user can
also disengage the locking device manually (thus canceling the escape and
return function) by holding his card two seconds in front of the lock's card
reader.
The signalling of the Escape&Return function can be switched off.
Example:
If a guest leaves their hotel room and smells smoke in the corridor, they can
go back into their room immediately.
Example 2:
Student residence / retirement home: In many cases, the user notices that
he forgot the card immediately after he or she closed the door. With
Escape & Return the user can solve this problem himself.
SmartHandle
SmartIntego
(Manual)
6. Designs
35 / 160
Summary of Contents for SI:SmartHandle Series
Page 1: ...SmartHandle SmartIntego Manual 28 10 2020...
Page 25: ...6 5 Distances and door thicknesses SmartHandle SmartIntego Manual 6 Designs 25 160...
Page 131: ...SmartHandle SmartIntego Manual 8 Installation manual 131 160...
Page 132: ...9 Outer fitting is mounted SmartHandle SmartIntego Manual 8 Installation manual 132 160...
Page 136: ...2 Remove the uppermost battery SmartHandle SmartIntego Manual 8 Installation manual 136 160...
Page 137: ...3 Screw on the inside fitting SmartHandle SmartIntego Manual 8 Installation manual 137 160...
Page 145: ...10 Configuration See TechGuide WO SVCN SmartHandle SmartIntego Manual 10 Configuration 145 160...
Page 147: ...12 Signal See TechGuide WO SVCN SmartHandle SmartIntego Manual 12 Signal 147 160...