background image

AD-200

OFFLINE LOCK USER GUIDE

INSTRUCTIONS FOR ADAPTABLE SERIES OFFLINE LOCKS

Para el idioma español, navegue hacia www.schlage.com/support.

Pour la portion française, veuillez consulter le site www.schlage.com/support.

P516-129

Summary of Contents for AD-200-CY

Page 1: ...NE LOCK USER GUIDE INSTRUCTIONS FOR ADAPTABLE SERIES OFFLINE LOCKS Para el idioma español navegue hacia www schlage com support Pour la portion française veuillez consulter le site www schlage com support P516 129 ...

Page 2: ... Mode 5 Locks with Keypads 5 Manual Lock Programming 6 Credential Types 6 Programming Legend 6 Using the Lock 8 Error Codes 9 Testing 9 Mechanical Testing 9 Electronic Testing 9 Resetting To Factory Defaults 10 LED Reference 10 Schlage Button 10 Optional Inside Push Button IPB 10 Batteries 11 Installing or Replacing Batteries 11 Low Battery Indications 11 Battery Failure Modes 11 External Power Su...

Page 3: ...11 or External Power Supply on page 12 for more information Outside lever is normally locked Inside lever always allows egress The lock maintains an audit trail of events Configured using the Handheld Device HHD See Handheld Device HHD on page 4 for more information Outside Schlage Button Outside Lever Keyway Inside Inside Push Button IPB Optional Thumbturn Inside Lever Battery Compartment Keypad ...

Page 4: ...ctronic operation See Testing on page 9 for more information 5 When ready to set up for normal use program the user credentials See Manual Lock Programming on page 6 for more information Î ÎProgramming the lock with the HHD will remove all credentials that were added using the master construction credential 6 Consult the Schlage Utility Software User Guide for information about configuring the loc...

Page 5: ...ancel Construction Access Mode Do one of the following Authenticate or program the lock with the HHD See the Schlage Utility Software User Guide for more information Reset the lock to factory settings See Resetting To Factory Defaults on page 10 for more information Create a new master programming PIN code When construction mode is cancelled the Master Construction Credential and all other credent...

Page 6: ...ozen until Freeze credential is presented again PIN 3 6 digits OR card Freeze PIN PIN 3 6 digits AND card Pass through Unlocks a lock momentarily regardless of state Overrides a lock in Freeze state PIN 3 6 digits OR card Pass through PIN PIN 3 6 digits AND card Programming Legend Symbol Description Programming Code Five digit code identical to programming credential code listed in the Credential ...

Page 7: ...e OR Programming Card Wait for to stop flashing between each step New PIN for PIN only OR New Card add another credential OR to finish Add Toggle Credential Programming Code OR Programming Card Wait for to stop flashing between each step New PIN for PIN only OR New Card add another credential OR to finish Add Toggle PIN Credential Programming Code OR Programming Card Wait for to stop flashing betw...

Page 8: ...ard Wait for to stop flashing between each step Credential PIN delete another credential OR to finish Change Relock Time Programming Code OR Programming Card Wait for to stop flashing between each step to add 1 second AND OR to add 5 seconds to finish 1 Other lights may show before the final confirmation Wait for the final confirmation before continuing to the next step USING THE LOCK After creden...

Page 9: ...the installation guide and correct any problems Mechanical Testing 1 Insert the key into the keyway and rotate the key or the key and the lever to open the door Operation should be smooth and the latch should retract 2 Insert the key into the keyway and rotate the key or the key and the outside lever to open the door Operation should be smooth and the latch should retract Electronic Testing 1 For ...

Page 10: ...ge Utility Software User Guide for more information Schlage Button Condition Lights Access denied 2 red blinks Access denied user outside time zone 4 red blinks Factory default reset Solid red while clearing memory then one second solid green when complete Waiting for PIN Card PIN Mode 0 only 5 left red with right green blinks then solid right green Low battery indicator AA batteries 9 left red bl...

Page 11: ...Coin Cell then normal indicator Replace batteries immediately to avoid battery failure Lock is intended to operate for 500 cycles in low battery condition Battery Failure configured by HHD No LED or beeps Valid credentials do not grant access Replace batteries immediately Mechanical override key must be used to unlock lock Battery Failure Modes Î ÎThe battery failure is set using the Handheld Devi...

Page 12: ...be connected to external power using a UL 294 Listed Power Supply capable of sourcing at least 250 mA 12 to 24 VDC Î ÎWhen powered with external power supply the lock will always fail As Is if power is lost Inside Polarity Required TROUBLESHOOTING For troubleshooting visit to www schlage com support ...

Reviews: