USER OPERATING INSTRUCTIONS
3750
Electronic Entry Device
OPENING THE LOCK
1. Enter valid combination (factory set to 1-2-3-4-5-6).
2. The lock will indicate a valid combination entry with a double signal.
3. Within four (4) seconds, turn the keypad to the open position (clock-wise) if using a
dead bolt style lock, or turn the handle to the open position if using a swing bolt
style
lock.
4. Pull door open.
•
Invalid Combination Entry
- Lock will signal three (3) times.
WRONG TRY PENALTY
• Entry of four (4) consecutive invalid combination starts a fi ve (5) minute delay period.
-
LED
fl ashes red at ten (10) second intervals.
• At the end of the delay period, two more consecutive invalid combination will restart
the
fi ve (5) minute delay period.
© copyright 2003-2008
(P/N) 755.118 Rev A • 12/08
Kaba Mas LLC
Page 1 of 2
FEATURES
See Manager Instructions for additional features.
USER COMBINATION
• Open Lock
• Change Combination
WRONG TRY PENALTY
• Four (4) consecutive invalid combination
initiates
fi ve (5) minute delay period.
LOW BATTERY WARNING
• Repeated LED fl ashing and beeping during
opening indicates battery is low and needs
immediate
replacement.
AUDIO AND VISUAL SIGNAL
• Double signal - two (2) LED fl ashes and two
(2) beeps - indicates entry is valid
or
accepted.
• Triple signal - three (3) LED fl ashes and
three (3) beeps - indicates invalid or
not
accepted.