Programming and Operating Manual (Milling)
224
6FC5398-4DP10-0BA1, 01/2014
Parameters in the window for timers and workpiece counters
①
The total number of workpieces produced (total
actual)
⑤
The run time of the selected NC program in seconds
The default value is 0 each time a new NC program
starts up. MD27860 can be set to ensure that this value
will be deleted even if there is a jump to the beginning of
the program with GOTOS or in the event of ASUBS
(used for tool change in "JOG" and "MM+" modes) and
PROG_EVENTs starting.
②
The number of workpieces required (workpiece
setpoint)
⑥
Processing time in seconds
③
The number of all workpieces produced since the
starting time
⑦
The time since the last control power up with default
values ("cold restart") in minutes
④
The total run time of NC programs in "AUTO" mode
and the run time of all programs between NC start
and end of program/RESET. The timer is set to
zero with each power-up of the control system.
⑧
The time since the last normal control power up ("warm
restart") in minutes
Note: The timer is automatically reset to zero in case of a control power-up with default values.
Modifying miscellaneous setting data
Operating sequence
1.
Select the desired operating area.
2.
Open the setting data window.
3.
Open the window for miscellaneous setting data.
4.
Select a group of setting data you desire to modify.