Programming and Operating Manual (Milling)
222
6FC5398-4DP10-0BA1, 01/2014
A.4
Entering/modifying work offsets
Operating sequence
In case of any problems found when testing the tool offset result, you can proceed through the following steps to make tiny
adjustment of values:
1.
Select the desired operating area.
2.
Open the list of work offsets. The list contains the values of the basic offset of the programmed
work offset and the active scaling factors, the mirror status display and the total of all active work
offsets.
3.
Use the cursor keys to position the cursor bar in the input fields to be modified and enter the values.
4.
Confirm your entries. The changes to the work offsets are activated immediately.
A.5
Entering/modifying the setting data
Entering/modifying the setting data
Operating sequence
1.
Select the desired operating area.
2.
Open the setting data window.
3.
Position the cursor bar in the input fields to be modified and enter the values (see table below for
the parameter descriptions).
4.
Use this key or move the cursor to confirm your entries.