Technical data
Table 7-13
Technical specifications for RF360T
6GT2800-4AC00
6GT2800-5AC00
Product type designation
SIMATIC RF360T
Memory
Memory organization
in bytes
Memory configuration
• UID
• 4 bytes EEPROM
• User memory
• 8 KB FRAM / 32 KB FRAM
• OTP memory
• 20 bytes EEPROM
Read cycles (at < 40 ℃)
> 10
10
Write cycles (at < 40 ℃)
> 10
10
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
)
Dependent on the reader used, see section "Field
data of RF300 transponders (Page 50)"
Mechanical specifications
Enclosure
• Material
• Epoxy resin
• Color
• Anthracite
Recommended distance to metal
≥ 20 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
• during write/read access
• -25 … +75 °C
• outside the read/write field
• -40 … +85 °C
• during storage
• -40 … +85 °C
Degree of protection according to EN 60529
IP67
Shock-resistant acc. to EN 60721-3-7, Class 7 M2
500 m/s
2
Vibration-resistant acc. to EN 60721-3-7, Class 7
M2
200 m/s
2
Torsion and bending load
Not permitted
Design, dimensions and weight
Dimensions (L x W x H)
86 x 55 x 2.5 mm
Weight
25 g
RF300 transponder
7.6 SIMATIC RF360T
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09