![Siemens SIMATIC RF300 System Manual Download Page 339](http://html.mh-extra.com/html/siemens/simatic-rf300/simatic-rf300_system-manual_374416339.webp)
Type of delivery
Minimum order quantity: 1250 units (5 rolls with 250 units each)
8.11.3
Technical data
Table 8-31
Technical specifications of MDS D261
6GT2600-1AA01-0AX0
Product type designation
SIMATIC MDS D261
Memory
Memory configuration
• UID
• 8 bytes
• User memory
• 256 bytes EEPROM
• OTP memory
• 16 bytes (EEPROM)
Read cycles (at < 40 ℃)
> 10
14
Write cycles (at < 40 ℃)
> 10
6
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
)
Dependent on the reader used, see section "Field
data of ISO transponders (MDS D) (Page 53)"
Mechanical specifications
Enclosure
• Material
• Top: PET (label material)
• Inlay: PET (carrier material)
• Antenna: Aluminum
• Bottom: Double-sided transfer adhesive on sili‐
con paper
• Color
• White
Recommended distance to metal
≥ 25 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
• during write/read access
• -20 ... +60 °C
• outside the read/write field
• -20 … +85 °C
• During transportation and storage
• +20 to +30 ℃
Can be stored for 2 years, determined by the dura‐
bility of the adhesive
Degree of protection
IP65
Design, dimensions and weight
ISO transponder
8.11 MDS D261
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09
339