![Siemens SIMATIC RF300 System Manual Download Page 99](http://html.mh-extra.com/html/siemens/simatic-rf300/simatic-rf300_system-manual_374416099.webp)
Substance
Test conditions
Rating
Concentration [%] Temperature [°C]
Lactic acid, w.
50%
20 ℃
++
10%
20 ℃
+++
10%
60 ℃
++
Sodium carbonate, w. (soda)
c. s.
60 ℃
++++
Sodium chloride, w.
c. s.
60 ℃
++++
Sodium hydroxide
-
60 ℃
++++
Nickel salts, w.
c. s.
60 ℃
++++
Nitrobenzene
-
20 ℃
+++
-
60 ℃
++
Phosphoric acid
10%
20 ℃
+
Propane
-
60 ℃
++++
Mercury
-
60 ℃
++++
Nitric acid
10%
20 ℃
+
Hydrochloric acid
10%
20 ℃
+
Sulfur dioxide
low
60 ℃
++++
Sulfuric acid
25%
20 ℃
++
10%
20 ℃
+++
Hydrogen sulfide
low
60 ℃
++++
Carbon tetrachloride
-
60 ℃
++++
Toluene
-
20 ℃
++++
-
60 ℃
+++
Detergent
high
60 ℃
++++
Plasticizer
-
60 ℃
++++
Explanation of the rating
++++
Resistant
+++
Practically resistant
++
Conditionally resistant
+
Less resistant
○
Not resistant
w.
Water solution
c. s.
Cold saturated
4.5.2
Transponder
4.5.2.1
Overview of the transponders and their housing materials
The following sections describe the resistance to chemicals of the various transponders.
Resistance to chemicals depends on the housing materials used to manufacture the
transponders.
Planning the RF300 system
4.5 Chemical resistance of the readers and transponders
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09
99