8.26.5
Dimension drawing
s
s
Figure 8-73
Dimensional drawing of MDS D524
All dimensions in mm
8.27
MDS D525
8.27.1
Characteristics
MDS D525
Characteristics
Area of application
Compact and rugged ISO transponder for screw mounting
Use in assembly and production lines in the powertrain sector;
ideal for mounting on motors, gearboxes, and workpiece hold‐
ers
Can also be deployed under extreme environmental condi‐
tions without problems due to the rugged design.
Memory size
8192 bytes of FRAM user memory
Write/read range
See section "Field data of ISO transponders (MDS D)
(Page 53)".
Mounting on metal
Yes
ISO standard
ISO 15693
Degree of protection
IP68/IPx9K
8.27.2
Ordering data
Table 8-72
Ordering data for MDS D525
Article number
MDS D525
6GT2600-5AG00
ISO transponder
8.27 MDS D525
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09