8.5
MDS D126
8.5.1
Characteristics
MDS D126
Characteristics
Area of application
Compact and rugged ISO transponder, suitable for iden‐
tification of transport units in production-related logis‐
tics.
Can also be deployed in harsh environmental condi‐
tions.
Memory size
112 bytes of EEPROM user memory
Write/read range
See section "Field data of ISO transponders (MDS D)
(Page 53)"
Mounting on metal
Yes, with spacer
ISO standard
ISO 15693
Degree of protection
IP68
8.5.2
Ordering data
Table 8-12
Ordering data for MDS D126
Article number
MDS D126
6GT2600-0AE00
Table 8-13
Ordering data for MDS D126 accessories
Article number
Spacer
6GT2690-0AL00
8.5.3
Mounting on metal
Direct mounting of the transponder on metal is not permitted. A distance of ≥ 20 mm is
recommended to avoid a reduced read/write range and a reduction of the field data. This can be
accomplished, for example, by installing a spacer.
Note that if the distances (a and h) are not observed, this may result in a reduction of the field
data as well as a reduced write/read range.
ISO transponder
8.5 MDS D126
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09