![Siemens SIMATIC RF300 System Manual Download Page 383](http://html.mh-extra.com/html/siemens/simatic-rf300/simatic-rf300_system-manual_374416383.webp)
8.22.4
Technical specifications
Table 8-62
Technical specifications for MDS D460
6GT2600-4AB00
Product type designation
SIMATIC MDS D460
Memory
Memory configuration
• UID
• 8 bytes
• User memory
• 2000 bytes FRAM
• OTP memory
• 16 bytes FRAM
Read cycles (at < 40 ℃)
> 10
12
Write cycles (at < 40 ℃)
> 10
12
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
)
Dependent on the reader used, see section "Field
data of ISO transponders (MDS D) (Page 53)"
Mechanical specifications
Enclosure
• Material
• Epoxy resin
• Color
• Black
Recommended distance to metal
≥ 10 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
• during write/read access
• -25 … +85 °C
• outside the read/write field
• -40 … +100 °C
• during storage
• -40 … +100 °C
Degree of protection according to EN 60529
• IP67
• IPx9K
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75
°C
Shock-resistant according to IEC 68-2-27
1)
500 m/s
2
Vibration-resistant according to IEC 68-2-6
1)
200 m/s
2
Torsion and bending load
Not permitted
Design, dimensions and weight
Dimensions (Ø x H)
16 x 3 mm
Weight
3 g
Type of mounting
• Glued
2)
• With spacer
ISO transponder
8.22 MDS D460
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09
383