Characteristics
MDS D425
Characteristics
Area of application
Compact and rugged ISO transponder for screw mounting
Use in assembly and production lines in the powertrain sector;
ideal for mounting on motors, gearboxes, and workpiece hold‐
ers
Can also be deployed under extreme environmental condi‐
tions without problems due to the rugged design.
Memory size
2000 bytes of FRAM user memory
Write/read range
See section "Field data of ISO transponders (MDS D)
(Page 53)".
Mounting on metal
Yes
ISO standard
ISO 15693
Degree of protection
IP68/IPx9K
8.19.2
Ordering data
Table 8-53
Ordering data of MDS D425
Article number
MDS D425