![Siemens SIMATIC RF300 System Manual Download Page 57](http://html.mh-extra.com/html/siemens/simatic-rf300/simatic-rf300_system-manual_374416057.webp)
Diameter of the transmis‐
sion window (L
d
)
Operating distance (S
a
)
Limit distance (S
g
)
MDS D425
17
1...10
14
MDS D428
17
1...15
20
MDS D460
15
1...12
16
MDS D521
10
0...4
6
MDS D522
20
1...10
13
MDS D524
25
1...27
35
MDS D525
17
1...10
14
MDS D528
17
1...15
20
MDS D560
15
1...12
16
All values are in mm
Table 4-18
Field data RF350R reader / ANT 30
Diameter of the transmis‐
sion window (L
d
)
Operating distance (S
a
)
Limit distance (S
g
)
MDS D124
30
1...35
40
MDS D126
70
1...42
50
MDS D160
25
1...24
28
MDS D324
30
1...35
40
MDS D422
30
1...14
16
MDS D423
45
5...22
28
MDS D424
28
1...45
50
MDS D425
25
1...15
20
MDS D426
65
1...45
48
MDS D428
25
1...25
28
MDS D460
22
1...18
20
MDS D522
30
1...15
18
MDS D524
28
1...45
50
MDS D525
25
1...15
20
MDS D526
65
1...45
48
MDS D528
25
1...25
28
MDS D560
22
1...18
20
All values are in mm
Table 4-19
Field data RF360R reader
Length of the transmission window
Operating distance
(S
a
)
Limit distance (S
g
)
in x direction (L
x
)
in the y direction
(L
y
)
MDS D100
115
90
5...110
140
MDS D124
75
60
2...60
75
Planning the RF300 system
4.2 Field data for transponders, readers and antennas
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09
57