8.21.5
Dimension drawing
2
4
+0.
2
18
+0.5
3.5
1
.7
0
.2
6
.5
6.5
M8
2
0
+1
3
1
0
3
13
R1
SW 22
Dimensions in mm
Figure 8-57
Dimension drawing of MDS D428
8.22
MDS D460
8.22.1
Characteristics
MDS D460
Characteristics
Area of application
Identification in small assembly lines
Can also be used in a harsh industrial environment without
problem
Memory size
2000 bytes of FRAM user memory
Write/read range
See section "Field data of ISO transponders (MDS D) (Page 53)"
Mounting on metal
Yes, with spacer
ISO standard
ISO 15693
Degree of protection
IP67/IPx9K
ISO transponder
8.22 MDS D460
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09