Technical specifications
Table 8-52
Technical specifications for the MDS D424
6GT2600-4AC00
Product type designation
SIMATIC MDS D424
Memory
Memory configuration
• UID
• 8 bytes
• User memory
• 2000 bytes FRAM
• OTP memory
• 16 bytes FRAM
Read cycles (at < 40 ℃)
> 10
12
Write cycles (at < 40 ℃)
> 10
12
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
)
Dependent on the reader used, see section "Field
data of ISO transponders (MDS D) (Page 53)"
Mechanical specifications
Enclosure
• Material
• Epoxy resin
• Color
• Black
Recommended distance to metal
≥ 15 mm
Power supply
Inductive, without battery
ISO transponder
8.18 MDS D424
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09
369