![Siemens SIMATIC RF300 System Manual Download Page 56](http://html.mh-extra.com/html/siemens/simatic-rf300/simatic-rf300_system-manual_374416056.webp)
Diameter of the transmis‐
sion window (L
d
)
Operating distance (S
a
)
Limit distance (S
g
)
MDS D421
7
0...4
5
MDS D521
7
0...3
4
All values are in mm
Table 4-15
Field data RF350R reader / ANT 8
Diameter of the transmis‐
sion window (L
d
)
Operating distance (S
a
)
Limit distance (S
g
)
MDS D117
3
0...4
5
MDS D127
3
0...4
5
MDS D421
4
0...3
4
MDS D521
4
0...3
4
All values are in mm
Table 4-16
Field data RF350R reader / ANT 12
Diameter of the transmis‐
sion window (L
d
)
Operating distance (S
a
)
Limit distance (S
g
)
MDS D117
2
0...2
3
MDS D127
2
0...3
4
MDS D160
15
0...8
12
MDS D421
6
0...2
3
MDS D428
15
1...10
17
MDS D460
8
1...8
10
MDS D521
6
0...2
3
MDS D528
15
1...10
17
MDS D560
8
1...8
10
All values are in mm
Table 4-17
Field data RF350R reader / ANT 18
Diameter of the transmis‐
sion window (L
d
)
Operating distance (S
a
)
Limit distance (S
g
)
MDS D117
3
0...5
6
MDS D124
27
2...24
28
MDS D127
3
0...5
6
MDS D160
20
1...18
20
MDS D324
25
1...22
28
MDS D421
10
0...4
6
MDS D422
20
1...10
13
MDS D424
25
1...27
35
Planning the RF300 system
4.2 Field data for transponders, readers and antennas
SIMATIC RF300
56