![Siemens SIMATIC RF300 System Manual Download Page 97](http://html.mh-extra.com/html/siemens/simatic-rf300/simatic-rf300_system-manual_374416097.webp)
Transponder
Reader RF382R (ISO mode)
Without metal
On metal
MDS D424
Without metal
100
105
1)
MDS D460
Without metal
100
115
1)
1)
Values of > 100 % can occur if transponders were developed specifically for mounting in/on metallic
surroundings.
4.4
Mechanical resistance of the readers and transponders
SIMATIC RF300 is a contactless identification system that meets high mechanical requirements
for shock and vibration (EN 60721-3-7 class 7). Use the readers/transponders only for their
intended use. They are not designed to withstand high mechanical stress and impact to the
enclosure may cause damage and failure.
4.5
Chemical resistance of the readers and transponders
4.5.1
Readers
4.5.1.1
Overview of the readers and their housing materials
Resistance to chemicals depends on the housing materials used to manufacture the reader. The
following table provides you with an overview of the housing materials that are used with the
RF300 readers:
Table 4-66
Overview of the materials of the reader components
Individual part of the reader
Housing material of the reader
Top cover and bottom
Polyamide 12;
The chemical resistance of this plastic is listed in the following section
"Polyamide 12".
Fiber-optic cable
Makrolon®2405
Decorative membrane
1)
Autotex V200
Socket
1)
Brass (copper alloy)
CuZn40Pb2
1)
Non-relevant component for resistance of complete housing
In case of questions please contact Siemens Support (section "Service & Support (Page 473)").
Planning the RF300 system
4.5 Chemical resistance of the readers and transponders
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09