![Siemens SIMATIC RF300 System Manual Download Page 362](http://html.mh-extra.com/html/siemens/simatic-rf300/simatic-rf300_system-manual_374416362.webp)
6GT2600-4AF00
• OTP memory
• 16 bytes FRAM
Read cycles (at < 40 ℃)
> 10
12
Write cycles (at < 40 ℃)
> 10
12
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
)
Dependent on the reader used, see section "Field
data of ISO transponders (MDS D) (Page 53)"
Mechanical specifications
Enclosure
• Material
• Plastic PA 6.6 GF; brass nickel plated
• Color
• Black/silver
Recommended distance to metal
≥ 0 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
• during write/read access
• -25 … +85 °C
• outside the read/write field
• -40 … +100 °C
• during storage
• -40 … +100 °C
Degree of protection according to EN 60529
IP68
2 hours, 2 bar, +20 °C
Shock-resistant acc. to EN 60721-3-7, Class 7M2
1)
500 m/s
2
Vibration-resistant acc. to EN 60721-3-7, Class
7M2
1)
200 m/s
2
Torsion and bending load
Not permitted
Design, dimensions and weight
Dimensions (Ø x H)
20 x 6 mm
Weight
13 g
Type of mounting
• Glued
2)
• 1 x transponder thread M20
≤ 1 Nm
Standards, specifications, approvals
MTBF
285 years
1)
The values for shock and vibration are maximum values and must not be applied continuously.
2)
The processing instructions of the adhesive manufacturer must be observed.
ISO transponder
8.16 MDS D422
SIMATIC RF300
362