![Siemens SIMATIC RF300 System Manual Download Page 51](http://html.mh-extra.com/html/siemens/simatic-rf300/simatic-rf300_system-manual_374416051.webp)
Table 4-3
Field data RF340R reader
Length of the transmission
window (L)
Operating distance (S
a
)
Limit distance (S
g
)
RF320T
45
1...20
25
RF330T
40
2...18
23
RF340T
80
2...50
58
RF350T
80
2...60
75
RF360T
90
2...65
85
RF370T
85
5...60
80
RF380T
90
5...80
100
All values are in mm
Table 4-4
Field data RF350R reader / ANT 1
Length of the transmission
window (L)
Operating distance (S
a
)
Limit distance (S
g
)
RF320T
45
1...30
37
RF330T
40
1...25
30
RF340T
80
2...55
70
RF350T
80
2...65
85
RF360T
90
2...75
100
RF370T
85
5...65
85
RF380T
90
5...90
110
All values are in mm
Table 4-5
Field data RF350R reader / ANT 3
Length of the transmission
window (L)
Operating distance (S
a
)
Limit distance (S
g
)
RF320T
25
1...15
18
RF330T
25
1...10
15
RF340T
40
2...25
30
All values are in mm
Table 4-6
Field data RF350R reader / ANT 18
Diameter of the transmis‐
sion window (L
d
)
Operating distance (S
a
)
Limit distance (S
g
)
RF320T
10
1...10
13
RF330T
10
1...11
13
RF340T
20
1...18
22
All values are in mm
Planning the RF300 system
4.2 Field data for transponders, readers and antennas
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09
51