IECEx
The SIMATIC Ident products meet the requirements of explosion protection acc. to IECEx. The
products meet the requirements of the standards:
Document
Title
IEC 60079-0
Hazardous areas
Part 0: Equipment - General requirements
IEC 60079-7
Hazardous areas
Part 7: Equipment protection by increased safety "e"
IEC 60079-31
Hazardous areas
Part 31: Equipment dust ignition protection by enclosure "t"
You will find the current versions of the standards in the currently valid IECEx certificates.
IECEx mark
NOTICE
Validity only when the devices are marked
There is a corresponding approval only with devices to which the IECEx mark is applied.
The identification of the electrical equipment is:
Ex ec IIB T4 Gc
Ex tc IIIC T80 °C Dc
-25 °C < Ta < +70 °C
IP64
U
n
= 24 V DC, 130 mA
The equipment also has the following additional information:
XXXYYYZZZ
[= serial number, is assigned during production]
IECEx ULD 17.0012 X
[= certificate number]
UL HAZ. LOC.
The SIMATIC Ident products meet the requirements of explosion protection acc. to UL HAZ. LOC.
The products meet the requirements of the standards:
Document
Title
UL 60079-0
Hazardous areas
Part 0: Equipment - General requirements
CSA C22.2 NO. 60079-0
UL 60079-7
Hazardous areas
Part 7: Equipment protection by increased safety "e"
CSA C22.2 NO. 60079-7
UL 60079-31
Hazardous areas
Part 31: Equipment dust ignition protection by enclosure "t"
CSA C22.2 NO. 60079-31