7ML19985QM82 XPS/XCT Series Transducers – OPERATION MANUAL
Page EN-5
English
Specifications
* Universal flange fits ANSI, DIN, and JIS standards.
** Approximate shipping weight of transducer with standard cable length.
*** EMC performance available upon request.
XPS-10
XPS-15
XPS-30
XPS-40
XCT-8
XCT-12
Measurement
Range
0.3 - 10 m
(1 - 33 ft)
0.3 - 15 m
(1 - 50 ft)
0.6 - 30 m
(2 - 100 ft)
0.9 - 40 m
(3 -130 ft)
0.6 - 8 m
(2 - 26 ft)
0.6 - 12 m
(2 - 40 ft)
Frequency (kHz)
44
44
30
22
44
44
Beam Angle
12
°
6
°
6
°
6
°
12
°
6
°
Environmental
Location
indoor/outdoor indoor/outdoor indoor/outdoor
indoor/outdoor indoor/outdoor indoor/outdoor
Maximum
Altitude (m)
2000
2000
2000
2000
2000
2000
Ambient
Temperature
-40 to 95
°
C
(-40 to 203
°
F)
-40 to 95
°
C
(-40 to 203
°
F)
-40 to 95
°
C
(-40 to 203
°
F)
-40 to 95
°
C
(-40 to 203
°
F)
-40 to 145
°
C
(-40 to 293
°
F)
-40 to 145
°
C
(-40 to 293
°
F)
Pressure
8 bar
(120 psi)
8 bar
(120 psi)
Europe: 0.5 bar
N. America: 15
psi
Europe: 0.5 bar
N. America: 15
psi
8 bar
(120 psi)
8 bar
(120 psi)
Pollution Degree
4
4
4
4
4
4
Construction
Housing
PVDF
PVDF
PVDF
PVDF
Standard
: PVDF
Optional
: Universal* sized
flange available with PTFE
facing
Mounting
1" NPT or
BSP conduit
connection
1" NPT or BSP
conduit
connection
1-1/2" NPT or
BSP conduit
connection
1-1/2" NPT or BSP
conduit
connection
1" NPT or BSP
conduit
connection
1" NPT or BSP
conduit
connection
Options
• factory bonded to suit ANSI, DIN, and JIS standards
• polyethylene foam facing for dusty or steamy environments
• submergence shield, where flooding can occur (available only for XPS-10, XPS-15)
• split flange for field mounting to suit ANSI, DIN, and JIS standards (not available for XPS-40)
Cable
2-wire twisted pair/braided
and foil shielded, 0.5mm² (20
AWG), PVC jacket
• 2-wire twisted pair/braided and
foil shielded, 0.5mm² (20 AWG),
PVC jacket
Maximum separation: 100 m
(330 ft)
• RG-62 A/U coax Maximum
separation: 365 m (1200 ft)
Silicon Jacket
Weight**
0.8 kg
(1.7 lb)
1.3 kg
(2.8 lb)
4.3 kg
(9.5 lb)
8 kg
(18 lb)
0.8 kg
(1.7 lb)
1.3 kg
(2.8 lb)
Maximum
Separation
365 m
(1200 ft)
365 m
(1200 ft)
365 m
(1200 ft)
365 m
(1200 ft)
365 m
(1200 ft)
365 m
(1200 ft)
Supply Source
Transducers shall only be supplied by Siemens Milltronics certified controllers
Approvals
CE***, CSA, FM, CENELEC/ATEX: See nameplate or consult Siemens Milltronics for current
approvals.
Summary of Contents for Echomax XCT Series
Page 1: ...Operation Manual February 2005 ECHOMAX xps xct ...
Page 2: ......
Page 12: ...Page EN 10 XPS XCT Series Transducers OPERATION MANUAL 7ML19985QM82 English ...
Page 22: ...Side DA 10 XPS XCT Serie Transducere DRIFTSVEJLEDNING 7ML19985QM82 Dansk ...
Page 32: ...Seite DE 10 Ultraschallsensoren XPS XCT BETRIEBSANLEITUNG 7ML19985QM82 Deutsch ...
Page 42: ...Σελίδα EL 10 Μορφοτροπείς σειρών XPS XCT ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ 7ML19985QM82 Ελληνικά ...
Page 52: ...Página ES 10 Sensores XPS XCT MANUAL DE OPERACIÓN 7ML19985QM82 Español ...
Page 62: ...Page FR 10 Transducteurs Série XPS XCT MANUEL D UTILISATION 7ML19985QM82 Français ...
Page 72: ...Pagina IT 10 Trasduttori serie XPS XCT MANUALE OPERATIVO 7ML19985QM82 Italiano ...
Page 82: ...Pagina NE 10 XPS XCT serie transducers BEDIENINGSHANDLEIDING 7ML19985QM82 Nederlands ...
Page 92: ...Página PT 10 Transdutores Séries XPS XCT MANUAL DE FUNCIONAMENTO 7ML19985QM82 Português ...
Page 102: ...sivu SU 10 XPS XCT sarjan anturit KÄYTTÖOPAS 7ML19985QM82 Suomi ...
Page 112: ...Sida SV 10 XPS XCT Transducerserier ANVÄNDNINGSMANUAL 7ML19985QM82 Svenska ...