Introduction
The Echomax XPS/XCT series of transducers operate with
Siemens Milltronics ultrasonic level monitoring products.
The transducer converts the electrical transmit pulse from the
transceiver into acoustical energy. It then converts the
acoustical energy of the echo back into electrical energy for the
controller.
The transducer face emits acoustical energy radiating outward,
decreasing in amplitude at a rate inversely proportional to the
square of the distance. Maximum power radiates
perpendicularly from the transducer face on the axis of
transmission. Where power is reduced by half (– 3 dB), a conical
boundary centered around the axis of transmission defines the
sound beam, the diameter of which is the beam angle.
The XPS/XCT transducers have an integrated temperature
sensor that reports the air temperature at the transducer to the controller.
General Guidelines
XPS/XCT Series – Certificate SIRA 99ATEX5153X
This equipment may be used in hazardous areas associated with all gases with temperature
classes T1, T2, T3 and T4 for the XPS series (XPS-10, XPS-15, XPS-30, and XPS-40) and T1, T2,
and T3 for the XCT series (XCT-8 and XCT-12). The XPS series is only certified for use in
ambient temperatures in the range of - 40 °C to 95 °C and the XCT series is only certified for
use in ambient temperatures in the range of -40 °C to 145 °C. Neither should be used outside of
their respective temperature ranges.
Installation shall be carried out in accordance with the applicable code of practice, and by
suitably trained personnel.
These devices should only be supplied from a circuit containing a suitably-rated fuse that has a
breaking capacity of 4000A. This fuse is included in Siemens Milltronics controllers.
Repair of this equipment shall be carried out in accordance with the applicable code of
practice.
WARNING:
Materials of construction are chosen based on their chemical
compatibility (or inertness) for general purposes. For exposure to specific
environments, check with chemical compatibility charts before installing.
transducer
transducer face
–3 db boundary
axis of
transmission,
perpendicular
to transducer
face
Summary of Contents for Echomax XCT Series
Page 1: ...Operation Manual February 2005 ECHOMAX xps xct ...
Page 2: ......
Page 12: ...Page EN 10 XPS XCT Series Transducers OPERATION MANUAL 7ML19985QM82 English ...
Page 22: ...Side DA 10 XPS XCT Serie Transducere DRIFTSVEJLEDNING 7ML19985QM82 Dansk ...
Page 32: ...Seite DE 10 Ultraschallsensoren XPS XCT BETRIEBSANLEITUNG 7ML19985QM82 Deutsch ...
Page 42: ...Σελίδα EL 10 Μορφοτροπείς σειρών XPS XCT ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ 7ML19985QM82 Ελληνικά ...
Page 52: ...Página ES 10 Sensores XPS XCT MANUAL DE OPERACIÓN 7ML19985QM82 Español ...
Page 62: ...Page FR 10 Transducteurs Série XPS XCT MANUEL D UTILISATION 7ML19985QM82 Français ...
Page 72: ...Pagina IT 10 Trasduttori serie XPS XCT MANUALE OPERATIVO 7ML19985QM82 Italiano ...
Page 82: ...Pagina NE 10 XPS XCT serie transducers BEDIENINGSHANDLEIDING 7ML19985QM82 Nederlands ...
Page 92: ...Página PT 10 Transdutores Séries XPS XCT MANUAL DE FUNCIONAMENTO 7ML19985QM82 Português ...
Page 102: ...sivu SU 10 XPS XCT sarjan anturit KÄYTTÖOPAS 7ML19985QM82 Suomi ...
Page 112: ...Sida SV 10 XPS XCT Transducerserier ANVÄNDNINGSMANUAL 7ML19985QM82 Svenska ...