The certification of this equipment relies on the following materials used in their construction:
For manual override, use the disconnect switch provided in the building installation of the
associated controller.
XPS 30/40 Series – Certificate SIRA 01ATEX5153X
This equipment may be used in hazardous dust zones with all conductive and non-conductive
dusts. The XPS-30 and XPS-40 type series transducers have a maximum surface temperature
of 135 °C (275 °F) (Temperature Class T4). These units are certified for use in ambient range of
-40 to 95 °C (-40 to 203 °F). The transducers should not be used outside this temperature range.
The XPS-30 and XPS-40 ultrasonic transducers must be installed so the face of the transducer
is not substantially subjected to light.
Installation shall be carried out in accordance with the applicable code of practice, and by
suitably trained personnel. Repair of the equipment shall be carried out in accordance with the
applicable code of practice and installation instructions.
These devices should only be supplied from a circuit containing a suitably rated fuse that has a
breaking capacity of 4000A. This fuse is included in Siemens Milltronics controllers.
The certification of this equipment relies on the following materials used in their construction:
For manual override, use the disconnect switch provided in the building installation of the
associated controller.
Product Marking
XPS-30
XPS Series
XCT Series
Enclosure
Kynar®
1
710
1.
Kynar®is a registered trademark of ELF Atochem.
Durapot®is a registered trademark of Cotronics Corporation.
Kynar®710
Encapsulant
Stycast LA-9823-76
Durapot® 861-F3 & 864
Enclosure:
Kynar®710
Encapsulant:
Stycast LA-9823-76
Note:
Kynar®polyvinylidene flouride is resistant to attack from most chemicals under the
described operating conditions. However, for exposure to specific environments, check
with chemical compatibility charts prior to installation.
WARNING:
This product is designated as a Pressure Accessory per Directive 97/
23/EC and is not intended for use as a safety device.
Summary of Contents for Echomax XCT Series
Page 1: ...Operation Manual February 2005 ECHOMAX xps xct ...
Page 2: ......
Page 12: ...Page EN 10 XPS XCT Series Transducers OPERATION MANUAL 7ML19985QM82 English ...
Page 22: ...Side DA 10 XPS XCT Serie Transducere DRIFTSVEJLEDNING 7ML19985QM82 Dansk ...
Page 32: ...Seite DE 10 Ultraschallsensoren XPS XCT BETRIEBSANLEITUNG 7ML19985QM82 Deutsch ...
Page 42: ...Σελίδα EL 10 Μορφοτροπείς σειρών XPS XCT ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ 7ML19985QM82 Ελληνικά ...
Page 52: ...Página ES 10 Sensores XPS XCT MANUAL DE OPERACIÓN 7ML19985QM82 Español ...
Page 62: ...Page FR 10 Transducteurs Série XPS XCT MANUEL D UTILISATION 7ML19985QM82 Français ...
Page 72: ...Pagina IT 10 Trasduttori serie XPS XCT MANUALE OPERATIVO 7ML19985QM82 Italiano ...
Page 82: ...Pagina NE 10 XPS XCT serie transducers BEDIENINGSHANDLEIDING 7ML19985QM82 Nederlands ...
Page 92: ...Página PT 10 Transdutores Séries XPS XCT MANUAL DE FUNCIONAMENTO 7ML19985QM82 Português ...
Page 102: ...sivu SU 10 XPS XCT sarjan anturit KÄYTTÖOPAS 7ML19985QM82 Suomi ...
Page 112: ...Sida SV 10 XPS XCT Transducerserier ANVÄNDNINGSMANUAL 7ML19985QM82 Svenska ...