2D Code
+ROI
Draw code outline, and the defined
search area.
Detailed Results
When writing the results to the table, all grades are written in one string (for example
“CACBAB”), making the detailed result occupying 6 rows in the table.
Symbol size
The symbol size used when decoding the 2D code.
X coordinate
Y coordinate
The X and Y coordinates of the 2D code that was decoded in
the image.
Angle
The rotation of the 2D code.
Mirrored code
Indicated whether or not the 2D code was mirrored:
0
Not
mirrored
1
Mirrored
Grades
Print quality grades according to ISO/IEC 16022:2000
Overall grade
Indicates the overall print quality of the 2D code.
Decode
Indicates whether the symbol was successfully decoded (A)
or not (F).
Symbol contrast
Indicates if the contrast between the dark and light cells in the
symbol is sufficient.
Print growth
Indicates if the dark or light cells are larger than the nominal
size.
Axial nonuniformity
Indicated if the 2D code is scaled unevenly.
Unused error correction
Indicates the extent to which damages in the symbol has
eroded the reading safety margin provided by the error
correction.