Read RS485 Values
This tool receives data through port RS485 and writes the values in the table. The received
values are successive filled in the table beginning at a selected start row.
Only transmit values up to 8 bit. Do not transmit any other values.
Input Parameters
01 = Timeout (ms)
Maximum time to receive one byte before an error
message occurs due to time out.
02 = Expected values
Total number of expected values.
Since the number of rows in the table are limited to
2000 the
Table index + Expected values
< 2001.
03 = Table index
Start row in table to write received values in a succes-
sive manner.
Returned Values
01 = Received bytes
Total number received values.
Error Messages
Err. = 407
Serial protocol
Check if a ‘Setup RS485’ tool was executed before
using this tool.
Check
Timeout in ms
.
Check if the number of
Expected values
is equal to
Received bytes.
The Emulator does
not emulate this
tool. See section
Handling the
Emulator for more
information.