Reference Manual
Chapter
4
IVC-2D
©
SICK AG • Advanced Industrial Sensors • www.sick.com • All rights reserved
115
Matching
02 = ROI definition step
A ROI that limits the part of the live image to transform.
03 = Shape locator step
The Shape Locator step that was used to find shapes.
04 = Shape index
The zero-based index of the shape to retrieve information
about.
05 = Interpolation
method
The interpolation method to use when calculating the pixel
values in the destination image.
06 = Destination bank
The image bank where the result shall be visualized. Set to
-1 if no visualization is used.
Returned Values
01 = Search status
The status of the execution of the 'Shape Locator' step.
SEARCH STATUS
The result Search status can have one of the following values
0 All
OK
8825 The reference point of the shape is located outside the image.
ERROR CODES
8810
The referenced step is not a Shape Locator step.
8812
The index of the shape is not valid, e.g. larger than the number of located
shapes.
8813
No results found from the Shape Locator tool. This can happen if the execution
of the Shape Locator tool failed for some reason.
8833