06=Relative threshold
Required change of gray value between bars and
spaces.
07=Interpolation method
Method to use when analyzing the thickness of the
bars:
Linear
Third-degree
08=Variable bar lengths
Specifies whether or not the bars in the image of
the barcode can have different thickness.
09=Normalization
Specifies whether or not the grayscale in the image
should be normalized before reading the barcode.
10=Display code
Specifies whether or not the read code should be
added to the image in the destination bank.
11=Use checksum
Specifies whether or not the read code should be
verified using the checksum in the barcode.
Checksums are only used in certain barcode types.
12=Min number of characters
The minimum number of characters to be read for
the barcode to be considered valid.
13=Destination bank
Image bank in which the resulting image will be
stored.
Returned Values
01=Error flag
Flag = 0 if the barcode was read without problems.
02=Read string
A string containing the code that was read.
03=Reading reliability
For Pharmacode barcodes, the percentage of the rea-
dings that were sucessful.
04=Edge has defects
Flag = 1 if there was any dark areas found in the edge
around the barcode