Communication
Communication Read/Write
The Communication read/write tool is used for updating values for parameters that are
read from the network, and to publish updated parameter values on the network, using
either the Ethernet/IP or the OPC protocol.
This tool is used for updating all values read from and published on the network. The
Read/write
parameter specifies whether the tool should update the values of subscribed
parameters, publish updated values for other devices to read, or both.
To specify which parameters to subscribe to and publish, use the 'Communication setup'
tool.
Input Parameters
01 = Read/Write
Specifies whether values should be read from the network,
written to the network, or both.
Read
Read updated values for the subscribed
parameters.
Write
Write updated values for the parameters
published on the network.
Read/Write
Read and write updated values.
Returned Values
None.
Error Messages
Err. = 8103
The value to write was too large for the type of the published
parameter, or would need to be rounded (was real when ex-
pected integer).
Allowed value ranges are:
SINT: -128
…
127
INT:
-32 768 … 32 767
DINT: -2 147 483 648 … 2 147 483 647
Err. = 8104
The value to write was a string when expecting a value, or a value
when expecting a string.
The Emulator does
not emulate this
tool. See section
Handling the
Emulator for more
information.